Assessing the Representativeness of Cell Sampling in Single Cell-ICP-MS Using Ru-Based Cell Size Markers and LA-ICP-MS
Mina Nikolić, Ana Lores-Padin, Thibaut Van Acker, Olivier De Wever, Frank Vanhaecke
Key points
From the paper's conclusion- These findings should be accounted for when developing novel SC-ICP-MS applications to ensure that reliable information is obtained.
Abstract
Single cell-inductively coupled plasma-time-of-flightmass spectrometry (SC-ICP-TOF-MS) enables high-throughput quantitative assay of endogenous and exogenous elements in individual cells. However, the low transport efficiency, inversely proportional to the cell size, raises a question: does SC-ICP-MS provide representative sampling of the original cell population, or are smaller cells preferentially measured? In this work, the occurrence and degree of size-dependent sampling bias were evaluated using laser ablation (LA)-ICP-TOF-MS, which enables cell size determination prior to analysis and achieves 100% cell transport efficiency. First, tagging protocols with Ruthenium red (RR) and ASCQ_Ruthenium (ASCQ_Ru) were thoroughly optimized to enable cell size estimation in SC-ICP-MS. To verify that both tags accurately capture size information, an automated LA-ICP-MS data processing pipeline was developed, revealing that the optically measured cell size distribution can be reliably predicted solely from the Ru cell content. This was verified across 4 distinct human cell types of different sizes (10−40 μm) and by analyzing up to 1000 cells per sample. While both tags successfully revealed cell size, ASCQ_Ru produced cleaner transient signals and did not influence the content of endogenous elements (i.e., P, S, Ca, Fe, Cu and Zn), whereas RR produced low-intensity non-cellular events and induced partial losses of Ca and Zn. Finally, the comparison of cell sizes based on LA-SC-ICP-MS and SC-ICP-MS revealed the existence of a slight size-dependent bias with a higher fraction of large cells observed by the former. These findings should be accounted for when developing novel SC-ICP-MS applications to ensure that reliable information is obtained.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Subcellular capillary sampling coupled to laser ablation – Inductively coupled plasma – Mass spectrometry (LA-ICP-MS) allows targeted analysis of thallium in a radiopharmaceutical modelSpectrochimica Acta Part B Atomic Spectroscopy · 2026
- Evaluating limits of detection for single-cell elemental bioimaging by LA-ICP-TOFMSTalanta · 2026
- Investigation and correction of size-dependent transport efficiencies of microparticles in SP ICP-MS analysisTalanta · 2026
- Single-Cell Insights into Size-Dependent Heterogeneous Bioconcentration and Distribution of Metal Species Ranging from Ions to Nanoclusters and Nanoparticles in Chlorella vulgaris.Environmental science & technology · 2026
- Nanoprobe XRF analysis reveals the intracellular distribution of organometallic rhenium complexes with different directing ligandFrontiers in Chemical Biology · 2026
- The use of mass cytometry (CyTOF) to evaluate the cellular uptake of stable radiopharmaceutical surrogates in single cells: a proof-of-concept studyEJNMMI Radiopharmacy and Chemistry · 2026