Mitochondria-Localized Three-Color Fluorescent Sensor for Concurrent Tracking of Mitochondrial H2O2, Hypochlorite and Subcellular Viscosity during Oxidative Stress and Drug-Related Hepatic Damage.
Xufeng Hou, Zhen Yang, Jiahui Li, Mengchao Guo, Zhihong Xu, Song Chen, Mingming Yu
Key Laboratory of Chemo/Biosensing and Detection of Xuchang, Key Laboratory of Micro-Nano Materials for Energy Storage and Conversion of Henan Province, Henan Joint International Research Laboratory of Nanomaterials for Energy and Catalysis, College of Chemical and Materials Engineering, Xuchang University, Xuchang461000, P. R. China. · College of Pharmacy, Qiqihar Medical University, Qiqihar161006, China.
Key points
From the paper's conclusion- We report a naphthalimide derived mitochondrial targeting fluorescent probe MT for real time simultaneous visualization of mitochondrial hydrogen peroxide (H2O2), hypochlorite (ClO−), and subcellular microviscosity, three key biomarkers closely associated with oxidative stress mediated drug induced liver injury.
Abstract
We report a naphthalimide derived mitochondrial targeting fluorescent probe MT for real time simultaneous visualization of mitochondrial hydrogen peroxide (H2O2), hypochlorite (ClO-), and subcellular microviscosity, three key biomarkers closely associated with oxidative stress mediated drug induced liver injury. Free MT shows negligible background fluorescence under physiological conditions, and each biomarker triggers well-separated emission bands: red emission at 680 nm for elevated viscosity, orange emission at 600 nm for H2O2, and green emission at 500 nm for ClO-. MT exhibits low detection limits of 123.24 nM for H2O2 and 6.34 nM for ClO-, enabling spectral crosstalk free triple channel readouts. We validated MT performance in ferroptosis and drug damaged hepatocyte cell models for in situ triple biomarker imaging. In vivo fluorescence imaging dynamically monitored acetaminophen provoked acute liver injury in mice; full three channel signals were only acquired from ex vivo liver slices due to tissue penetration constraints. This sensitive multichannel probe provides a practical tool to dissect liver pathological progressions and quantitatively evaluate hepatoprotective agents in preclinical liver injury models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-response mitochondria-targeted fluorescent probe for Hypochlorous acid and viscosity: Applications in liver injury diagnosis and environmental monitoring.Bioorganic chemistry · 2026
- Stepwise Design of a High Signal-to-Background Ratio Dual-Emission Probe for Imaging Mitochondrial HClO and Microenvironmental Changes in Diabetic Liver and Kidney Injury.Analytical chemistry · 2026
- Real-Time Monitoring Ferroptosis-Mediated Drug-Induced Liver Injury Using a Near-Infrared Mitochondrial Viscosity Probe.Analytical chemistry · 2026
- Tuning Lipophilicity to Develop an MMP-Independent Fluorescent Probe for Visualizing Mitochondrial Peroxynitrite in Drug-Induced Liver InjuryAnalytical Chemistry · 2026
- A mitochondria-anchored dual-lock probe for sequential detection of HOCl and viscosity during oxidative stress and ferroptosisChemical Communications · 2025
- A Mitochondria-Targeted Fluorescent Probe for the Real-Time Tracking of Hypochlorous Acid During Inflammation.ACS biomaterials science & engineering · 2026