Nucleic Acid Amplification Boosts Electrochemically Addressable Probe Networks for Ultrasensitive Plate-Based Electrochemiluminescence Immunoassays.
Tengyu Li, Yu Liang, Ziyang Wang, Jiayi Cao, Ziqi Lian, Yajuan Yan, Wenxuan Fu, Haitao Yu,
Zhejiang Key Laboratory of Excited-State Energy Conversion and Energy Storage, Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou310058, China. · Department of Clinical Laboratory, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou310016, China.
Key points
From the paper's conclusion- Herein an electrochemically addressable probe network-based ECL immunoassay (EAPN-ECLIA) was developed, in which rolling circle amplification (RCA) converts target recognition into a densely labeled ruthenium probe network at the carbon electrode interface.
Abstract
Electrochemiluminescence immunoassays (ECLIAs) offer low-background and highly sensitive protein biomarker detection, but their performance is often severely limited by the poor electrochemical accessibility of luminophore labels in bulky immunocomplexes. Herein an electrochemically addressable probe network-based ECL immunoassay (EAPN-ECLIA) was developed, in which rolling circle amplification (RCA) converts target recognition into a densely labeled ruthenium probe network at the carbon electrode interface. The RCA-generated DNA scaffold recruits biotinylated probes and Ru-labeled streptavidin, increasing Ru-complex loading while positioning a portion of Ru-labels sufficiently close to the electrode surface for direct electrooxidation and efficient ECL generation. In addition, a constraint-aware scoring and ranking algorithm was proposed to guide the selection of carbon-based electrode materials for ECLIAs. Compared with conventional plate-based ECLIA, EAPN-ECLIA improved detection sensitivity by approximately 5000-fold. For plasma phosphorylated Tau181, a key Alzheimer's disease biomarker, the platform achieved a limit of detection of 85.81 fg/mL, reliable plasma recovery, and effective discrimination of patients with AD from healthy controls with an area under the curve of 0.9650. This strategy highlights electrochemical addressability, rather than luminophore loading alone, as a key design principle for ultrasensitive ECLIAs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Magnetic Rolling Circle Amplification-Assisted Automated Electrochemiluminescence Immunoassay for Ultrasensitive Determination of Protein BiomarkersAnalytical Chemistry · 2025
- Ultrasensitive and Multiplex Detection of RNAs with Single-Nucleotide Resolution Using Lambda Exonuclease-Assisted Probe Signal Amplification-Rolling Circle Amplification.ACS sensors · 2026
- Autonomous Exponential Amplification via Rolling Circle–DNAzyme Feedback ProgrammingJournal of the American Chemical Society · 2025
- Phosphorylation-asymmetric recombinase polymerase amplification enables target-directed circularization for ultrasensitive multiplex electrochemical detection of respiratory pathogens.Mikrochimica acta · 2026
- Electrochemiluminescence-based multiplex immunoassays for multianalyte bioanalysis: Signal encoding strategies and analytical perspectivesElectrochemistry Communications · 2026
- An Engineered Supramolecular Pathway for Enhanced Electrochemiluminescence.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026