LITES Sensing Based on an Ultra-Compact Plane-Spherical Multi-Pass Cell Designed via Multi-Objective Algorithm of NSGA-III and K-Means Clustering
Haiyue Sun, Xiaorong Sun, Ying He, Shunda Qiao, Yufei Ma
Key points
From the paper's conclusion- To overcome the trade-off between optical path length (OPL) and physical volume (V) in conventional multi-pass cell (MPC) design, and to address the issues of uncontrollable spot patterns and susceptibility to interference fringes in dense spot configurations, this work proposes a novel automatic design paradigm of multi-objective optimization for ultra-compact plane-spherical MPC by synergizing t
Abstract
To overcome the trade-off between optical path length (OPL) and physical volume (V) in conventional multi-pass cell (MPC) design, and to address the issues of uncontrollable spot patterns and susceptibility to interference fringes in dense spot configurations, this work proposes a novel automatic design paradigm of multi-objective optimization for ultra-compact plane-spherical MPC by synergizing the non-dominated sorting genetic algorithm III (NSGA-III) with K-Means clustering for the first time. In this method, K-means clustering is transformed from a mere post-processing tool into an intrinsic objective function that quantifies the regularity of the spot distribution, which is then fed into the NSGA-III engine. This enables the simultaneous multi-objective optimization of OPL, OPL-to-volume ratio (RLV), spot uniformity, and inter-spot safety spacing. Using this autonomous design approach, an ultra-compact MPC with a recorded RLV of 48.18 cm−2 is achieved, enabling automatically controllable dense spot patterns while effectively avoiding optical crosstalk and overlap. Experimental results demonstrate excellent agreement between the measured and simulated spot patterns for three designed spot configurations (concentric two-rings, independent 17-rings, and independent nine-rings). An acetylene (C2H2) light-induced thermoelastic spectroscopy (LITES) sensor with the independent 17-ring MPC (volume of only ∼16 mL) was constructed for performance validation, achieving a minimum detection limit of 6.1 ppb and exhibiting a concentration linearity of 0.99. This demonstrates that the proposed auto-designed MPC method, based on the synergy of NSGA-III and K-means clustering, realizes a breakthrough integration of ultra-high sensitivity and field-ready miniaturization for gas sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Large-Aperture Inverse-Designed Sparse Meta-Optics in the Mid-Wave Infrared.ACS nano · 2026
- Smart SPR Biosensors: Machine Learning‐Augmented Dual‐Channel PCF TechnologyAdvanced Photonics Research · 2026
- Simultaneous dual-analyte detection biosensor through a stacking-based ensemble machine learning approach: design and optimizationBiomedical Optics Express · 2026
- Prediction and inverse design of effective optical properties of polymer nanocomposites empowered by machine learning.Optics letters · 2026
- Accelerating photonic gas sensor design: machine learning-driven inverse optimization of silicon photonics Bragg gratingsScientific Reports · 2026
- A Data‐Driven Co‐Optimization Framework to Concurrently Enhance Lightweight Performance and Micro‐Vibration‐Induced Imaging Stability of Space Optical SystemsJournal of Mechanical Design · 2026