Key points
From the paper's conclusion- To assist MS users in understanding and characterizing this m/z bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion detection.
Abstract
The analysis of high molecular weight or heterogeneous macromolecules is a significant analytical challenge. This is especially the case in mass spectrometry, where heterogeneity results in unresolved signal in m/z from which charge, and thus mass, information cannot be discerned. Recent developments in mass spectrometry-based approaches overcome these challenges by the simultaneous detection of m/z and charge, and their expanded application has been aided by the development of commercial instrument platforms for transmitting large, heterogeneous molecules. However, the characterization of heterogeneous species that span a broad range in m/z, such as glycoproteins, polysaccharides, or polymers, is still particularly challenging due to m/z bias that is induced by the conventional approach of tuning a mass spectrometer for optimal transmission over a narrow window in m/z. To assist MS users in understanding and characterizing this m/z bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion detection. On the basis of this knowledge, practical recommendations for instrument tuning are presented with the aim of mitigating m/z bias and standardizing mass spectrum data reporting. The main target audience of this tutorial are bio-, synthetic or analytical chemists with an interest in the characterization of heterogeneous molecules and mixtures, or scientists interested in understanding each of the factors that contribute to the generation of a mass spectrum on one of the most widely used commercial instrument platforms in the world.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Benchmarking the Performance of a Commercial Electrostatic Linear Ion Trap (ELIT) Charge Detection Mass Spectrometer For Higher-Order Antibody Aggregate AnalysisbioRxiv · 2026
- Molecule by Molecule Characterization of a Polymer Molecular Mass Distribution via Mass PhotometryAngewandte Chemie International Edition · 2026
- Evaluating Batch Correction Methods for Large-Scale Mass Spectrometry Imaging of Heterogeneous TissuesAnalytical Chemistry · 2026
- Best practice mass photometry: a guide to optimal single-molecule mass measurementNature Protocols · 2025
- Super-resolved mass photometry reveals the dissociation pathways of individual protein complexesbioRxiv · 2026
- Benchmarking Automated Mass Photometry against SEC-MALS and AUC for Quantifying Cross-Linked Monoclonal Antibody Aggregates.The AAPS journal · 2026