Analytical chemistry

Smartphone-Assisted Electrochemiluminescence Imaging Platform Based on Protamine-Enhanced Gold Nanoclusters for Ultrasensitive and Visualized Detection of Zearalenone.

Tingting Han, Jinyang Zhuang, Kai Zhou, Enwei Zhu, Lin Zhao, Gang Wang, Yue Cao, Zixuan Chen,

Jiangsu Key Laboratory of Food Quality and Safety, Key Laboratory for Control Technology and Standard for Agro-product Safety and Quality, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing210014, PR China. · State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry, Nanjing University, Nanjing210023, PR China.

Computational

Key points

From the paper's conclusion
  • Herein, a portable smartphone-assisted electrochemiluminescence (ECL) imaging platform was developed for ultrasensitive and visualized detection of ZEN based on protamine-enhanced 6-aza-2-thiothymine-stabilized gold nanoclusters (Prot/ATT-Au NCs) synthesized by a protein-assisted assembly strategy.

Abstract

Zearalenone (ZEN) contamination in grains poses a serious threat to human and animal health, yet existing imaging-based platforms for rapid visualized detection remain limited by insufficient sensitivity, limited luminescence efficiency, and poor signal stability, hindering further practical applications. Herein, a portable smartphone-assisted electrochemiluminescence (ECL) imaging platform was developed for ultrasensitive and visualized detection of ZEN based on protamine-enhanced 6-aza-2-thiothymine-stabilized gold nanoclusters (Prot/ATT-Au NCs) synthesized by a protein-assisted assembly strategy. The resulting Prot/ATT-Au NCs achieved a 108-fold enhancement in ECL intensity relative to bare ATT-Au NCs and demonstrated an ECL efficiency approximately 5.01-fold higher than that of the benchmark Ru(bpy)32+ system, enabling naked-eye-visible green ECL emission. This enhancement was attributed to Prot-induced hydrogen-bonding and electrostatic confinement that suppressed nonradiative decay and facilitated radiative transitions. Integrated with catalytic hairpin assembly amplification, the developed ECL imaging system allowed ZEN to be visually quantified over a wide linear range of 1 pg/mL to 10 μg/mL with a detection limit of 0.38 pg/mL, along with excellent specificity, stability, reproducibility, and real-sample recoveries. Furthermore, it was applied for the determination of ZEN in naturally contaminated corn samples. This work provides a facile strategy for engineering high-performance ECL emitters and offers a robust route toward portable food safety monitoring.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers