Analytical chemistry

Simple and Isolation-Free Analysis of Tumor-Derived Extracellular Vesicles by Aggregation-Modulated Deterministic Lateral Displacement for Breast Cancer Classification.

Xueer Huang, Ting Wu, Haixia Li, Jinyu Liu, Bihong Diao, Jiayi Xiao, Lihong Liu

Guangdong Provincial Key Laboratory of New Drug Screening, NMPA Key Laboratory for Research and Evaluation of Drug Metabolism, School of Pharmaceutical Sciences, Southern Medical University, Guangzhou510515, China. · Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou510515, China.

Key points

From the paper's conclusion
  • Clinical validation using serum samples from 153 individuals yielded AUC values of 0.9806 for BC detection and 0.9642 for TNBC classification.

Abstract

Tumor-derived extracellular vesicles (EVs) are increasingly recognized as potential biomarkers for breast cancer (BC) diagnosis and molecular subtyping; however, most current analytical methods rely on laborious EV isolation and sophisticated instrumentation, limiting their routine clinical implementation. Herein, we report an aggregation-modulated deterministic lateral displacement (AM-DLD) platform for simple, label-free analysis of tumor-derived EVs without EV isolation. In this strategy, aptamer-functionalized polystyrene microspheres convert nanoscale EV recognition into microscale microsphere aggregates through target EV-mediated cross-linking, enabling direct analysis using a conventional DLD chip. Because EV-induced aggregation generates microsphere aggregates with heterogeneous sizes, a weighted lateral displacement index (LDI) was developed to integrate particle distributions across multiple DLD outlets into a single quantitative readout. Using EpCAM-positive EVs for BC detection and PD-L1-positive EVs for triple-negative BC (TNBC) classification, the AM-DLD platform achieved limits of detection of 8.20 × 105 and 1.67 × 106 particles mL-1, respectively, together with high linearity, specificity, stability, and recovery. Clinical validation using serum samples from 153 individuals yielded AUC values of 0.9806 for BC detection and 0.9642 for TNBC classification. This work establishes a generalizable signal-conversion strategy that extends conventional DLD technology from microscale particle manipulation to nanoscale biomarker analysis, providing an analytical platform for EV-based liquid biopsy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers