Theoretical Assessment of the Potential Kinetic Advantage of Spiky Particle Columns for Liquid Chromatography.
Sander Deridder, Yassine El Alali, Ali Moussa, Alessandra Adrover, Gert Desmet
Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050Brussels, Belgium. · Dipartimento di Ingegneria Chimica Materiali Ambiente, Sapienza Università di Roma, 00185Rome, Italy.
Key points
From the paper's conclusion- We report on a computational study to gain insights into the potential advantage of spiky particles in packed bed columns for liquid chromatography.
Abstract
We report on a computational study to gain insights into the potential advantage of spiky particles in packed bed columns for liquid chromatography. Using the recently adopted Two-Zone Moment Analysis method, a comprehensive set of band broadening data has been generated over an exhaustive range of particle/spike combinations and shapes, velocities, diffusion coefficients, and retention factors. It has been found, under the strict limitation of the presumed perfect ordering of the particles, that the spikes can be expected to lead to a drastic decrease of the beds' flow resistance φ (up to a factor of 10 and more) compared to the no-spike case. This is due to the increase in external porosity ε caused by the spikes keeping the particles further away from each other. The presence of the spikes, however, also leads to an increased band broadening, albeit that this increase is much more modest than the decrease in flow resistance. This leads to the overall situation that spiky particles, if they could be produced with sufficient mechanical strength and size uniformity, could offer a way to significantly lower the minimal separation impedance Emin (=hmin2.φ) of packed-bed HPLC columns. In the hypothetical, perfectly ordered particle packings considered in the present study, Emin dropped with a factor ranging between 3 and 12, depending on the length of the spikes (longest spikes give the lowest impedance). However, to truly benefit from these low separation impedances in the plate number range of main practical interest, the spiky particles would require ultra-small particle diameters, down to and even well below 1 μm.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wall-induced dispersion in multicapillary columns with diffusional bridging.Journal of chromatography. A · 2026
- Packed-bed characterization of microfluidic liquid chromatography columns using breakthrough curve analysis.Journal of chromatography. A · 2026
- Solute pulse compression and spreading in power-law fluid flow through a semipermeable tubearXiv · 2026
- Mechanistic Origins of Pressure Reduction, Apparent Efficiency Gain, and Enhanced Detector Response in Radial Flow Stream Splitting Chromatography.Journal of separation science · 2026
- Catheter-modulated transient solute dispersion in micropolar annular flow with a retentive and absorptive arterial wallarXiv · 2026
- Comparison of ultrahigh- and low-pressure packing methods for preparation of 50 cm long capillary UHPLC columns.Journal of chromatography. A · 2026