Aldehyde-Functionalized Eu(III) Helicate for l-Cysteine-Specific CPL Detection through Cyclization-Induced M-Helix Excess.
Min Fan, Jianxu Zhang, Sen Yin, Jingya Li, Ting Gao, Li Li, Yanyan Zhou, Hongfeng Li
Key Laboratory of Function Inorganic Material Chemistry, Ministry of Education; School of Chemistry and Materials Science, Heilongjiang University, 74 Xuefu Rood, Harbin150080, China. · State Key Laboratory of Baiyunobo Rare Earth Resource Researches and Comprehensive Utilization Institution, Baotou014030, China.
Key points
From the paper's conclusion- Benefiting from the large glum value, the probe exhibited the high sensitivity for l-Cys in water or bovine serum albumin (BSA), with a detection limit lower than 8.11 × 10-7 M.
Abstract
l-Cysteine (Cys) levels are linked to many health issues and serve as critical diagnostic criteria for various diseases. However, their highly specific recognition and determination from complex biological matrices remain challenging due to interference from biothiol-containing analogs, such as homocysteine (Hcy) and glutathione (GSH). Herein, by strategically positioning eight aldehyde groups at the periphery of a dinuclear Eu(III) helicate, we achieved the specific determination of l-Cys via an induced negative circularly polarized luminescence (CPL) signal (gmax ≈ -1.22, 595 nm). 1H NMR and ESI-MS combined with single-crystal X-ray crystallography and DFT calculations revealed that the size match between the periphery pocket in the helicate and the thiazolidine ring formed by l-Cys and aldehyde cyclization contributed to this CPL response, which creates a large energy difference (∼37.6 kcal/mol) between diastereoisomers and a M-helical preference. While the L-Hcy only resulted in a weak and positive signal (glum ≈ 0.15) due to the larger ring size, the GSH was CPL silent due to the non-cyclization reaction. Benefiting from the large glum value, the probe exhibited the high sensitivity for l-Cys in water or bovine serum albumin (BSA), with a detection limit lower than 8.11 × 10-7 M. Additionally, to facilitate commercial applications, a "test strip-like" hydrogel hybrid film was prepared, which still retains sensing capability to l-Cys. This work therefore provides a strategy for l-Cysteine detection by virtue of induced helical chirality of metallosupramolecules and strong lanthanide CPL.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rigid Eu(III) Helicates Exhibit Remarkable Circularly Polarized Luminescence Activity and Naked-Eye Recognition toward TizanidineJournal of the American Chemical Society · 2026
- Spiro-helicenoid Carbofluoresceins: CPL-Active Emitters for Bioimaging.Organic letters · 2026
- Rational Design of Rigid Chiral Ir(III)–Eu(III) Dyads: Intense Circularly Polarized Luminescence via Visible-Light SensitizationInorganic Chemistry · 2026
- Construction of Homochiral Covalent Organic Frameworks as Enantioselective Probes for Homogeneous Photoelectrochemical-Red–Green–Blue Dual-Mode Selective Sensing of d -CysteineAnalytical Chemistry · 2025
- Twisting Rhodamine─Design of Bright Dyes for Circularly Polarized FluorescenceJournal of the American Chemical Society · 2026