A Dual-Target-Activatable Ruthenium(II) Probe for Naked-Eye Luminescence-Guided Intraoperative Glioma Resection.
Jiabin Di, Run Shi, Jianqin Yan, Wenlong Liu, Zhihong Sun, Jie Cao, Yong Sun, Chaolong Liu
Department of Pharmaceutics, School of Pharmacy, Yantai Yuhuangding Hospital, Qingdao Medical College, Qingdao University, Qingdao266071, China.
Key points
From the paper's conclusion- To the best of our knowledge, Ru-GA is the first dual-target-activated probe reported for luminescence-guided intraoperative glioma resection with naked-eye visibility.
Abstract
Glioma is the most common primary malignant tumor of the central nervous system and represents a devastating disease associated with high mortality and severe neurological morbidity. Currently, surgical resection remains the cornerstone of glioma therapy. However, gliomas are characterized by highly infiltrative growth, which makes tumor boundaries difficult to distinguish under conventional white-light visualization. Therefore, there is an urgent clinical need for imaging approaches that enable high-contrast and high-sensitivity visualization to assist surgeons in delineating glioma margins. In this study, we developed a low-background luminescent Ru(II) complex probe, Ru-GA, which enables luminescence-guided intraoperative glioma resection with naked-eye visibility via dual-target recognition of glutathione S-transferases (GSTs) and azoreductase (AzoR). In this probe, a 2,4-dinitrophenyl ether group and an azobenzene group are introduced into the Ru(II) complex luminophore for the specific recognition of GSTs and AzoR, respectively. Owing to the strong electron-withdrawing effect of the 2,4-dinitrophenyl and azobenzene moieties, strong photoinduced electron transfer and intramolecular charge transfer processes occur within the probe, leading to an efficient quenching of the luminescence of the Ru(II) complex, thus ensuring a low background for imaging. Upon sequential reaction with GSTs and AzoR, the dinitrophenyl group is cleaved off, and the azo group is reduced to amino groups; consequently, the luminescence is restored. Cellular imaging results indicate that both GSTs and AzoR are significantly overexpressed in glioma cells, and the probe successfully distinguishes glioma cells from normal brain cells via luminescence imaging. Meanwhile, the probe is excited by blue light and emits red light, with no spectral overlap between the excitation and emission. Based on these properties, Ru-GA enables luminescence-guided intraoperative glioma resection with naked-eye visibility. For the first time, we validated the feasibility of luminescence-guided resection of human glioma using human glioma tissue sections. To the best of our knowledge, Ru-GA is the first dual-target-activated probe reported for luminescence-guided intraoperative glioma resection with naked-eye visibility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Two-dimensional NIR-II AIE nanotheranostic probes with ultralarge Stokes shifts for surgical navigation and ablation of gliomaScience Advances · 2026
- Super-resolution gated-phosphorus-rhodamines for glioblastoma accurate diagnosis.Chemical science · 2026
- Multimodal Imaging of Live Cells and Tumor Spheroids by a G-Quadruplex DNA Selective Ru(II)Polypyridyl Probe.Chemistry (Weinheim an der Bergstrasse, Germany) · 2026
- High-Throughput Discovery of Near-Infrared Oxazine Probes for Fluorescence-Guided Glioblastoma Surgery.Cancers · 2026
- Enzyme-Activatable Probe for Tumor Bimodal Imaging, Intraoperative Navigation, and Urinalysis.Advanced healthcare materials · 2026
- A GGT-Activatable Chiral Gadolinium Polymer Probe for Dual-Modal MR/NIRF Imaging of Glioma.Advanced healthcare materials · 2026