A Novel "On-Off-On" Electrochemiluminescence Biosensor from Multifunctional AuPt Triangular Nanoprisms/Carbon Nitride Nanosheets.
Fang-Fang Xin, Jingxian Li, Futing Wang, Yujin Li, Changxiao Song, Siyu Long, Yifan Lyu, Dan Yang,
Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo and Biosensing, College of Material Science and Engineering, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Changsha, Hunan410082, China. · Department of Chemical Engineering, The University of Western Australia, Perth, Western Australia6009, Australia.
Key points
From the paper's conclusion- In this study, a novel electrochemiluminescence (ECL) biosensor is constructed by employing multifunctional gold-platinum triangular nanoprisms decorated on carbon nitride nanosheets (AuPt/CN) and an exonuclease III (Exo III)-assisted target recycling amplification strategy for the ultrasensitive detection of miRNA-499 via an "on-off-on" readout.
Abstract
In this study, a novel electrochemiluminescence (ECL) biosensor is constructed by employing multifunctional gold-platinum triangular nanoprisms decorated on carbon nitride nanosheets (AuPt/CN) and an exonuclease III (Exo III)-assisted target recycling amplification strategy for the ultrasensitive detection of miRNA-499 via an "on-off-on" readout. CN nanosheets work as an excellent ECL luminophore, while AuPt TNPs enhance catalytic activity and electron-transfer capability and boost ECL emission. The AuPt/CN-modified glassy carbon electrode (AuPt/CN/GCE) produces a strong initial ECL signal, i.e., "on" status. Subsequent binding of ferrocene (Fc)-labeled hairpin DNA (H-Fc) via Au-S bonds, brings the -Fc group close to AuPt/CN/GCE, resulting in the quenching of the ECL signal of H-Fc/AuPt/CN/GCE, i.e., "off" status. When miRNA-499 is present, the Exo III-assisted recycling amplification strategy is activated: miRNA-499 hybridizes with H-Fc to form miRNA-499/H-Fc/AuPt/CN/GCE, and Exo III selectively cleaves the blunt 3'-terminus of H-Fc. As a result, the Fc group is removed from the AuPt/CN/GCE surface, while miRNA-499 is released to trigger the next amplification cycle and restore the ECL signal, i.e., "on" status. The as-designed ECL biosensor can ultrasensitively detect miRNA-499 with a detection limit (LOD) of 0.07 fM (S/N = 3) in the range of 0.1 fM to 10 nM.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ce-doped BiF3@Pt nanocatalyst enhanced CHA-based electrochemical biosensor for sub-femtomolar detection of miRNA-21.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Bifunctional CuPt Nanoclusters and DSN-Mediated Target Recycling Enabled Dual-Mode OPECT/Colorimetric Biosensing for Ultrasensitive and Wide-Range Detection of miRNA-21.Analytical chemistry · 2026
- CoMn Nanosheets Mediate Water-Driven Luminol Electrochemiluminescence via Coupled Electrocatalysis and Nanozyme Activity for BiosensingAnalytical Chemistry · 2026
- Dual-Functional Nanoconfined Metal-Organic Frameworks with Aggregation-Induced Electrochemiluminescence Coupled with DNAzyme Motor for Ultrasensitive miRNA-21 Biosensing.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Electrochemiluminescence Resonance Energy Transfer Biosensor Based on Self-Enhanced Terbium-Based Metal–Organic Frameworks with Antenna Effect for Sensitive MicroRNA-155 DetectionAnalytical Chemistry · 2025
- Synergistic cascade amplification by catalytic hairpin assembly and terminal deoxynucleotidyl transferase for ultrasensitive detection of microRNA-21.Talanta · 2026