Analytical chemistry

A Novel "On-Off-On" Electrochemiluminescence Biosensor from Multifunctional AuPt Triangular Nanoprisms/Carbon Nitride Nanosheets.

Fang-Fang Xin, Jingxian Li, Futing Wang, Yujin Li, Changxiao Song, Siyu Long, Yifan Lyu, Dan Yang,

Molecular Science and Biomedicine Laboratory, State Key Laboratory of Chemo and Biosensing, College of Material Science and Engineering, College of Chemistry and Chemical Engineering, College of Biology, Hunan University, Changsha, Hunan410082, China. · Department of Chemical Engineering, The University of Western Australia, Perth, Western Australia6009, Australia.

Key points

From the paper's conclusion
  • In this study, a novel electrochemiluminescence (ECL) biosensor is constructed by employing multifunctional gold-platinum triangular nanoprisms decorated on carbon nitride nanosheets (AuPt/CN) and an exonuclease III (Exo III)-assisted target recycling amplification strategy for the ultrasensitive detection of miRNA-499 via an "on-off-on" readout.

Abstract

In this study, a novel electrochemiluminescence (ECL) biosensor is constructed by employing multifunctional gold-platinum triangular nanoprisms decorated on carbon nitride nanosheets (AuPt/CN) and an exonuclease III (Exo III)-assisted target recycling amplification strategy for the ultrasensitive detection of miRNA-499 via an "on-off-on" readout. CN nanosheets work as an excellent ECL luminophore, while AuPt TNPs enhance catalytic activity and electron-transfer capability and boost ECL emission. The AuPt/CN-modified glassy carbon electrode (AuPt/CN/GCE) produces a strong initial ECL signal, i.e., "on" status. Subsequent binding of ferrocene (Fc)-labeled hairpin DNA (H-Fc) via Au-S bonds, brings the -Fc group close to AuPt/CN/GCE, resulting in the quenching of the ECL signal of H-Fc/AuPt/CN/GCE, i.e., "off" status. When miRNA-499 is present, the Exo III-assisted recycling amplification strategy is activated: miRNA-499 hybridizes with H-Fc to form miRNA-499/H-Fc/AuPt/CN/GCE, and Exo III selectively cleaves the blunt 3'-terminus of H-Fc. As a result, the Fc group is removed from the AuPt/CN/GCE surface, while miRNA-499 is released to trigger the next amplification cycle and restore the ECL signal, i.e., "on" status. The as-designed ECL biosensor can ultrasensitively detect miRNA-499 with a detection limit (LOD) of 0.07 fM (S/N = 3) in the range of 0.1 fM to 10 nM.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers