Analytical chemistry

Adaptive Integrated Microfluidic System with Real-Time Dielectric Feedback for Deterministic Micro-Manipulation.

Yichi Zhang, Zihe Guo, Langlang Yang, Zihao Li, Zhimeng Zhang, Wenping Geng, Zhangbin Ji, Ruiying Wang,

State Key Laboratory of Widegap Semiconductor Optoelectronic Materials and Technologies, North University of China, Taiyuan, Shanxi 030051, China. · Shanxi Key Laboratory of Ferroelectric Physical Micro-Nano Devices and Systems, North University of China, Taiyuan, Shanxi 030051, China.

Key points

From the paper's conclusion
  • Here, we introduce an adaptive integrated microfluidic system (AIMS) that implements a closed-loop sensing−decision−actuation−verification control framework via on-chip integration of dual-frequency impedance cytometry (IFC) and tunable traveling surface acoustic waves (T-TSAW).

Abstract

Conventional microfluidic particle sorting systems predominantly rely on static, open-loop operational principles, rendering them highly vulnerable to performance deterioration induced by cellular phenotypic heterogeneity and localized hydrodynamic fluctuations. Here, we introduce an adaptive integrated microfluidic system (AIMS) that implements a closed-loop sensing-decision-actuation-verification control framework via on-chip integration of dual-frequency impedance cytometry (IFC) and tunable traveling surface acoustic waves (T-TSAW). An upstream IFC array (1#IFC) performs real-time, label-free electrical interrogation of single-cell dielectric phenotypes. These transient signals are processed in real time by a custom finite-state machine (FSM) algorithm to dynamically modulate the downstream T-TSAW field. Concurrently, a downstream IFC array (2#IFC) performs post-sorting verification and feeds real-time state metrics back to the FSM core. This initiates an adaptive hill-climbing optimization loop to enable continuous acoustic frequency calibration. The system performance was rigorously evaluated using monodisperse polystyrene microspheres and biologically relevant colloidal models. The closed-loop architecture successfully isolated target MCF-7 cells from an erythrocyte-dominated simplified blood model, achieving an acoustic sorting efficiency of 95 ± 1.5% and a purity of 94 ± 2.5%. Furthermore, continuous adaptive sorting of primary mouse immune cell populations (PBMCs and neutrophils) was demonstrated, achieving a sorting efficiency of 92 ± 1.8% and a purity of 93 ± 6.7%. Ultimately, the seamless integration of transient electronic sensing algorithms with multiphysics mechanical actuation establishes a highly robust architectural framework for autonomous microelectromechanical manipulation platforms.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Adaptive Integrated Microfluidic System with Real-Time Dielectric Feedback for Deterministic Micro-Manipulation — Science Skim