High-Precision and Low-Interference Measurement of Total OH Reactivity Based on the Comparative Reactivity Method (CRM).
Yuqing Qiu, Xin Li, Yi Liu, Shengrong Lou, Mengdi Song, Hongli Wang, Qingyan Fu, Yuanhang Zhang
College of Environmental Sciences and Engineering, Peking University, Beijing100871, China. · School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai200094, China.
Key points
From the paper's conclusion- These results demonstrated that the modified CRM system provided high-precision, low-interference OHR measurement across diverse atmospheric environments, extending the applicability of the CRM to complex, high-NOx conditions.
Abstract
The comparative reactivity method (CRM) had been widely applied for measuring the total OH reactivity (OHR) due to its portability and cost-effectiveness. However, conventional CRM systems suffer from large uncertainties under high-NOx conditions because of secondary OH• formation and long gas residence times. In this study, we developed a technically modified CRM system that featured a redesigned single-channel, short-residence flow tube (residence time = 1.2 s), which substantially reduced secondary OH• formation from NO-HO2• reactions and largely suppressed NO-RO2• interference while reducing pyrrole photolysis from 25% to 2%. The system was coupled with a Vocus Proton Transfer reaction time-of-Flight Mass Spectrometer (Vocus PTR-ToF-MS) for high time-resolution detection of pyrrole. Laboratory calibrations using various volatile organic compound (VOC) standards demonstrated excellent linearity (r2 >0.990) over a reactivity range of 0-120 s-1. Furthermore, we implemented real-time humidity correction and an optimized multi-component interference correction framework for NO, NO2, and O3, with the estimated uncertainties on the measured OHR being 5%, 5%, 10%, and 4% for humidity, NO, NO2, and O3, respectively. The total measurement uncertainty was estimated to be 15%. The modified CRM system achieved a detection limit of 2.1 s-1, and the field data were averaged to 5 min to match the temporal resolution of the LP-LIF measurements for subsequent intercomparison. Field measurements were conducted at an urban site in Beijing (high-NOx) and at Longquan Mountain (low-NOx), showing strong agreement with simultaneous laser flash photolysis-laser-induced fluorescence instrument (LP-LIF) measurements, with regression slopes of 1.064 (r2 = 0.939) in Beijing and 0.992 (r2 = 0.952) at Longquan Mountain. These results demonstrated that the modified CRM system provided high-precision, low-interference OHR measurement across diverse atmospheric environments, extending the applicability of the CRM to complex, high-NOx conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond Targeted Calibrations: Comprehensive Quantification of Oxygenated Organic Compounds in Urban Atmospheres.Environmental science & technology · 2026
- Photochemical Impacts from Resolving Isomers and Interference Biases in PTR-ToF-MS Measurements of Atmospheric VOCs.Environmental science & technology · 2026
- A rapid prediction method for estimating ozone reaction with anthropogenic organic compounds in the pollutant release and transfer register (PRTR) system.Journal of hazardous materials · 2026
- Real-time direct detection of Criegee intermediates from ozonolysis of alkenes in an atmospheric simulation chamberScience Advances · 2026
- Tropospheric OH and its trends: new insight into atmospheric processes and implications for methane lifetimeAtmospheric Chemistry and Physics · 2026
- Reassessing Ozone Formation: How Photochemical VOC Loss Unmasks Biases in Radical Pathway DiagnosisJournal of Geophysical Research: Atmospheres · 2026