In Situ Visualization of Tumor and Drug-Induced Liver Injury with AIEgens, Polarity-Responsive, Membrane-Targeting Fluorescent Probes.
Peng Lei, Xiaojing Chai, Pengjia Wei, Chuan Dong, Youhong Tang, Shaomin Shuang, Minglu Li
College of Chemistry and Chemical Engineering & Institute of Environmental Science, Shanxi University, Taiyuan030006, China. · Institute for NanoScale Science and Technology, College of Science and Engineering, Flinders University, Adelaide, South Australia5042, Australia.
Key points
From the paper's conclusion- Probemem-1 and Probemem-2 served as efficient molecular tools to track polarity changes, which could facilitate the mechanistic exploration of liver injury.
Abstract
Dynamic changes in the polarity of the cellular microenvironment play a pivotal role in drug-induced liver injury (DILI) and tumors, serving as a crucial biomarker for evaluating cell membrane integrity and functional status. Precise monitoring of polarity changes is essential for elucidating the underlying mechanisms of injury. However, the real-time and specific visualization of local polarity remains a considerable challenge. Herein, polarity-sensitive fluorescent probes Probemem-1 and Probemem-2 were successfully developed. The structures adopted a D-π-A configuration, where a triphenylamine unit served as the electron donor, 1,3-indanedione acted as the electron acceptor, and the two were linked via a thiophene or dithiophene bridge. The triphenylamine moiety endowed Probemem-1 and Probemem-2 with unique aggregation-induced emission (AIE) properties. The fluorescence lifetimes of Probemem-1 and Probemem-2 were markedly prolonged in low-polarity media, demonstrating their pronounced sensitivity to environmental polarity. Importantly, Probemem-2 exhibited better photostability compared to Probemem-1. Analysis of the DILI mouse models revealed a significant correlation between decreased liver polarity and aggravated injury, indicating the potential of polarity as a biomarker for assessing DILI severity. Probemem-1 and Probemem-2 served as efficient molecular tools to track polarity changes, which could facilitate the mechanistic exploration of liver injury.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Membrane-Targetable Dual-Responsive Fluorescent Probe for Simultaneous Detection of Polarity and Hypochlorite and Its Application in Apoptosis and Cancer ModelsAnalytical Chemistry · 2026
- Incorporating quaternary ammonium to engineer a dual-targeting, dual-channel aggregation-induced emission probe for in situ imaging of lymphoma and drug-induced liver injury.Mikrochimica acta · 2026
- A polarity-sensitive fluorescent probe for targeted lipid droplets imaging and in vivo visualization of non-alcoholic fatty liver disease.Talanta · 2026
- Design and synthesis of a methylation-modified bifunctional fluorescent probe with Tunable ACQ-AIE transition for ultrasensitive detection of trace water and polarity in lipid droplets and lysosomes.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- A novel tetrahydrocarbazole derivative-based lysosome-targeted fluorescent probe for the detection of apoptosis and polarity change in biological system.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Targeted Lifetime Probe Enables Quantitative FLIM Mapping of Lipid Droplet Polarity Remodeling under Copper-Induced Oxidative Stress.Analytical chemistry · 2026