Fiber-Optic Photoacoustic Dual-Gas Analyzer Based on a Symmetric Four-Cone Converging Cell with Dual-Frequency Resonance.
Chun Sun, Jingya Zhang, Heng Wang, Chenxi Li, Xiao Han, Hongchao Qi, Ke Chen
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning116024, China. · School of Dalian University of Technology and Belarusian State University Joint Institute, Dalian University of Technology, Dalian, Liaoning116024, China.
Key points
From the paper's conclusion- A symmetric four-cone converging photoacoustic (PA) cell with dual-frequency resonance is proposed for the simultaneous measurement of two gases.
Abstract
A symmetric four-cone converging photoacoustic (PA) cell with dual-frequency resonance is proposed for the simultaneous measurement of two gases. The resonance tubes are designed as conical frustums rather than conventional cylinders reducing cell volume. Finite element optimization equalizes the amplitudes of the two resonance peaks at 2850 and 4220 Hz. A high-sensitivity cantilever transducer is used to transmit the PA signals to a fiber-optic demodulator. The operating frequencies of the two lasers are each locked to half of their respective resonant frequencies. A dual-channel digital lock-in amplifier is used to measure the PA signals of acetylene and methane in two distinct frequency channels. Due to the special tube geometry, conventional circular spots based on matrix transmission theory are inapplicable. A linear light spot matching the tube shape is designed using a 4Lf imaging system and spherical reflection, achieving 25 reflections and a 9.93 m optical path length. Compared with double-pass absorption, the signal is amplified by 19.69 times. Crosstalk analysis showed signal crosstalk of -104.9 dB and frequency crosstalk of -110.1 dB. For trace gas analysis, two distributed feedback (DFB) lasers with operating wavelengths of 1532.8 nm for C2H2 at 50.2 mW and 1653.7 nm for CH4 at 51.3 mW are employed. The laser models are DFB-1532.8 and DFB-1653.7 from Xiao Xiao Photonics, respectively. At 1 s integration time, the 1σ minimum detection limits (MDLs) for the two gases reach 3.94 and 20.3 ppb, respectively. Meanwhile, the noise-equivalent absorption (NNEA) coefficients are 2.26 × 10-10 W·cm-1·Hz-1/2 and 6.47 × 10-10 W·cm-1·Hz-1/2, respectively.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Synergistic Dual-Resonant Enhancement in Miniaturized Spiral-Architected Fiber-Optic Photoacoustic Spectroscopy for Ultra-Sensitive Gas AnalysisAnalytical Chemistry · 2026
- Stepped-Type Photoacoustic Resonator for Simultaneous Dual-Gas DetectionAnalytical Chemistry · 2026
- Tuning fork-cantilever coupled dual-resonance fiber-optic photoacoustic sensor for simultaneous dual-gas detection.Optics letters · 2026
- Small-Volume Hollow Cell-Based High-Sensitivity Cantilever-Enhanced Photoacoustic Gas Analyzer.Analytical chemistry · 2026
- Coupled Multi-Parameter Optimization of a Differential Resonant Photoacoustic Cell with Impedance-Matched Pickup for Trace Acetylene Detection.Sensors (Basel, Switzerland) · 2026
- Simultaneous Detection of Dual-Component Gases Using a Single Multipass Photoacoustic Cell with Cross-Patterned SpotsAnalytical Chemistry · 2026