Phosphate Anions Promote the Electromigration of Charge-Inversed TPE[14]aneN4 in a Homogeneous Electrochemiluminescence System for Kanamycin Detection.
Hailin Lv, Zifeng Li, Wenqian Luo, Bingxian Peng, Jianbin Pan, Ling Chen, Dianping Tang, Juan Tang
National Engineering Research Center for Carbohydrate Synthesis, Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Materials, Jiangxi Normal University, Nanchang330022, People's Republic of China. · State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing210023, P. R. China.
Key points
From the paper's conclusion- Thus, to achieve sensitive detection, an "off-on" ECL bioassay was constructed based on TPE[14]aneN4 as emitters by combing host-guest interaction.
Abstract
Homogeneous electrochemiluminescence (ECL) assay has emerged as a research hotspot due to its facile operation and high stability. Among the reported homogeneous ECL systems so far, the intensity of ECL signals is mainly regulated by changing the migration rate of luminophores toward the electrode, while the influence of ions in the base solution on signal intensity is rarely taken into consideration. In this study, a positively charged amphiphilic TPE[14]aneN4 was synthesized to explore the effect of its interaction with phosphate anions on ECL signal intensity. TPE[14]aneN4 can self-assemble into spheres, and the quaternary ammonium cationic groups (-NR4+) on the surface can interact with phosphate anions to achieve charge inversion. After positive voltage is applied, these particles can migrate toward electrodes more rapidly and generate intense ECL signals. Thus, to achieve sensitive detection, an "off-on" ECL bioassay was constructed based on TPE[14]aneN4 as emitters by combing host-guest interaction. After TPE[14]aneN4 is loaded into the γ-cyclodextrin (γ-CD), it remains in a dispersed state and interacts weakly with phosphate anions, resulting in weak ECL signals. When the kanamycin (Kana) is added, the released S1-Au-α-Amylase can cleave γ-CD, prompting TPE[14]aneN4 to reaggregate into spheres with phosphate anions and S1-Au-α-Amylase on the surface and boosting the ECL signal intensity. The sensor exhibits a linear relationship between ECL intensity and concentration within the range of 1.0 × 10-10 M to 1.0 × 10-5 M, with a 9.56 pM limit of detection, achieving sensitive detection of Kana. And the detection results are highly consistent with those of standard methods, demonstrating excellent application value.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Parallel Bipolar Electrode Array Modified by Hetero-Charged Silica Nanochannels for Ratiometric Electrochemiluminescence Detection of Escherichia coli Lysed by T4 PhageACS Sensors · 2026
- Phosphonium and ammonium fluorescein for selective detection of HSO₄− and CN− ions in aqueous mediaNew Journal of Chemistry · 2026
- Self-Enhanced Luminophore with an Intrinsically Integrated "Energy Ladder" and CdIn2S4-Enabled Coreactant Activation for Electrochemiluminescence Sensing.ACS sensors · 2026
- An electrochemiluminescent aptasensor based on porphyrin-based covalent organic framework for the sensitive detection of kanamycin.Talanta · 2026
- Coupling Electron Transfer with Ion Transport-Amplified Electrochemiluminescence SignalsAnalytical Chemistry · 2026
- Nanoconfinement catalysis-enhanced electrochemiluminescence aptasensor for the sensitive detection of matrix metalloproteinase-9RSC Advances · 2026