Analytical chemistry

Ultrasensitive and Specific Detection of Neutralization-Correlated Serum Antibodies Via Secondary Antibody-DNA Linker-Mediated Magnetic Bead-Based Proximity Extension Assay.

Long Zhao, Yujue Wang, Lin Xiao, Shiyu Cao, Wei Wang, Feng Ye

Department of Pathology, Institute of Clinical Pathology, Frontiers Science Center for Disease-related Molecular Network, West China Hospital, Sichuan University, Chengdu, Sichuan610041, China. · Department of Pathology, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Ministry of Education), West China Second Hospital, Sichuan University, Chengdu, Sichuan610041, China.

Key points

From the paper's conclusion
  • Integrating this linker into a magnetic bead-based proximity extension assay (termed SADL-MPEA), we achieved femtomolar-level detection of serum antibodies highly correlated with neutralizing activity.

Abstract

Sensitive, accurate, and readily deployable detection of neutralizing antibody (NAb) titers is essential for evaluating vaccine efficacy and population-level immunity. Here, we report an Antibody-DNA Linker (AND Linker) comprising a fusion of Protein A/G, a G4S flexible peptide, and duck circovirus replication initiator protein (DCV). This design enables orthogonal, site-specific assembly: the N-terminal Protein A/G binds the IgG Fc region, while the C-terminal DCV covalently captures 5' ssDNA at a defined 1:1 molar ratio. Unlike random chemical crosslinking, which suffers from heterogeneous attachment sites, variable stoichiometry, and poor reproducibility, the AND Linker ensures uniform functional orientation and minimal batch-to-batch variation. By optimizing ssDNA secondary structure, we further enhanced DCV recognition efficiency. Integrating this linker into a magnetic bead-based proximity extension assay (termed SADL-MPEA), we achieved femtomolar-level detection of serum antibodies highly correlated with neutralizing activity. For HPV16 and HPV18, SADL-MPEA demonstrated limits of detection (LOD) approximately three orders of magnitude lower than conventional PEA using random chemical conjugation. In clinical serum validation against the pseudovirus neutralization test (PBNT), SADL-MPEA showed strong concordance (Pearson's r = 0.84-0.85), confirming its utility as a reliable surrogate for functional neutralization capacity. Diagnostic performance was exceptional, with sensitivities of 90.9% (HPV16) and 83.3% (HPV18), 100% specificity for both, and an area under the ROC curve of 0.99. Crucially, SADL-MPEA requires only antigen-coated magnetic beads to adapt to new targets, as the DNA-labeled secondary antibody remains universal. This platform offers a simple, high-throughput, and scalable solution for NAb-correlated antibody detection in research and clinical settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers