A Combined Chemical Ionization and Photoelectron Ionization Source for TOFMS: Application to Online Detection of Aldehydes in End-Tidal Exhaled Breath.
Jing Li, Haijie Wang, Yingzhe Guo, Ruidong Liu, Jichuang Kong, Dong Yang, Jing Wang, Qingyi Zheng,
Environment Research Institute, Shandong University, Qingdao266237, China.
Key points
From the paper's conclusion- In exhaled breath analysis, CI and PEI stages are used for the simultaneous detection of aldehydes and CO2, respectively, enabling rapid determination of aldehyde biomarkers in exhaled breath combined with the CO2 conditions.
Abstract
In conventional exhaled breath analysis, a CO2 sensor is typically deployed separately from a biomarker detection instrument. Herein, we developed an all-in-one ionization source that integrates chemical ionization (CI) and photoelectron ionization (PEI) within a single hardware system, with the CI stage enabling highly sensitive detection of organic compounds and the PEI stage facilitating accurate quantification of inorganic species. NO+ was adopted as the reagent ion in the CI stage for efficient ionization of aldehydes to form [M + H]+ characteristic ions. The five-stage differential vacuum system and inverted-funnel high-pressure ion molecule reactor design introduced into the CI module enhanced the detection sensitivity toward dehydrated aldehydes by 1.63-24.13 times compared with the previously developed chemical ionization focusing integrated ionization source. Under optimal conditions, the limits of quantification for 10 aldehydes were as low as 0.28 to 86.77 pptv with a single analysis time of 1 s, and both intraday and interday relative standard deviations are below 11%. In exhaled breath analysis, CI and PEI stages are used for the simultaneous detection of aldehydes and CO2, respectively, enabling rapid determination of aldehyde biomarkers in exhaled breath combined with the CO2 conditions. Ultimately, the system was successfully deployed for the end-tidal breath analysis of healthy controls, smokers, and drinkers, accurately capturing distinct aldehyde signatures across different exposure cohorts, demonstrating its practicability and reliability in noninvasive medical diagnostics and metabolomic screening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid Screening of Aldehydes by SICRIT-HRMS: Understanding Ionization Behavior in Breath Analysis.ACS measurement science au · 2026
- Humidity-Controlled NO+ Chemical Ionization of Aldehydes through Association-Enabled Water-Mediated Protonation.Analytical chemistry · 2026
- Exhaled Aldehydes and Ketones as Biomarkers of Lung Cancer and Diabetes: Review of Sensor Technologies for Early Disease DiagnosisBiosensors · 2025
- Three-Dimensional COF/rGO/AuNP Porous Membranes for Enrichment-Enhanced Surface Enhanced Raman Scattering Detection of Aldehydes in Exhaled Breath.ACS applied materials & interfaces · 2026
- High-resolution FAIMS-mass spectrometry for breath analysis using atmospheric pressure chemical ionisation.Journal of breath research · 2026
- Selective and sensitive dual channel sensing of cyanide by bithiophene fluorophore-based D-π-A type chemodosimeters - Spectral and theoretical studies.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026