Analytical chemistry

Single-Tube Six-Channel Ultrafast PCR with Melting-Curve Discrimination for Seven Respiratory Pathogens.

Yang Li, Yi-Nuo Zhao, Xiang Li, Ting Sun, Lin-Wei Zhu, Miao-Jin Zhu, Li-Guo Liang, Hang-Ping Yao

State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, National Clinical Research Center for Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou310000, China. · School of Laboratory Medicine and Bioengineering, Hangzhou Medical College, Hangzhou311399, China.

Key points

From the paper's conclusion
  • Combined with a lyophilized-bead cartridge that automates nucleic acid release (4 min) and an ultrafast PCR run (16 min), the platform detects eight targets─seven respiratory pathogens (SARS-CoV-2, influenza A H1N1/H3N2/H5N1 clade 2.3.4.4b, influenza B Victoria/Yamagata, and Mycoplasma pneumoniae) plus one internal control (B2M)─using only six optical channels.

Abstract

Expanding single-tube multiplexing beyond the number of fluorescence channels on a real-time PCR instrument is a persistent challenge for point-of-care testing (POCT). Here, we break this barrier by leveraging melting temperature (Tm) as an extra information dimension. By employing a probe-cleavage-mediated reporter-duplex strategy, we circumvent the conventional limitation that hydrolyzed TaqMan probes cannot participate in postamplification melting analysis. Two FAM-labeled probes, each containing an engineered 5'-terminal nontarget extension, generate cleavage-dependent reporter amplicons with distinctly different melting temperatures (ΔTm = 10.3 °C), enabling precise differentiation between BV (72.5 °C) and BY (82.8 °C) within a single optical channel. Combined with a lyophilized-bead cartridge that automates nucleic acid release (4 min) and an ultrafast PCR run (16 min), the platform detects eight targets─seven respiratory pathogens (SARS-CoV-2, influenza A H1N1/H3N2/H5N1 clade 2.3.4.4b, influenza B Victoria/Yamagata, and Mycoplasma pneumoniae) plus one internal control (B2M)─using only six optical channels. The assay achieves a limit of detection of 5 copies per reaction (R2 > 0.97, amplification efficiency 96-104%) with no cross-reactivity against 55 nontarget microorganisms, and intra/inter-assay CVs < 5%. The lyophilized beads remain stable for 12 months at 25 °C (ΔCt < 1.5). In 272 clinical throat swabs, the system shows 100% agreement with single-plex qPCR. Mixed BV/BY infections produce two distinct melting peaks, with the low-abundance peak detectable down to a 400:1 ratio under the tested conditions. This six-channel ultrafast PCR system reliably detects eight targets in one tube within 20 min without extra hardware, providing a generic strategy for higher-order multiplexing in point-of-care settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers