Adaptive Approach Strategy for Efficient Scanning Ion Conductance Microscopy Based on Non-monotonic Approach Curves.
Qiangqiang Zheng, Lulu Kang, Wenlin Wu, Sheng Shi, Huan Yang, Jian Wang, Jian Zhuang
Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an710049, China. · Tangdu Hospital, Fourth Military Medical University, Xi'an710038, China.
Key points
From the paper's conclusion- These findings validate the potential of the adaptive scanning approach to overcome the scanning speed limitations of SICM, improving both imaging efficiency and quality.
Abstract
Scanning ion conductance microscopy (SICM) enables high-resolution, noncontact, in situ characterization of specimens in liquid environments, providing simultaneous access to three-dimensional (3D) topographical, electrical, and mechanical properties. Despite its versatility, the inherent imaging principle limits scanning speed, presenting a significant challenge to further development. This work introduces an adaptive scanning strategy leveraging the distinctive nonmonotonic ("rise-then-fall") approach curve observed in asymmetric self-referenced SICM (ASR-SICM). By employing a two-stage approach strategy, the nanopipette modulates its velocity based on its proximity to the sample surface, thereby enhancing both temporal resolution and imaging fidelity. The effectiveness of the proposed method was evaluated through finite element simulations and theoretical calculations, where the influences of electrolyte configuration and nanopipette structural parameters on the approach curve and feedback range were systematically analyzed. Additionally, the impact of different threshold settings on scanning time was examined. Subsequently, approach curves under different electrolyte conditions were measured on PDMS substrates, and the imaging accuracy was evaluated using fixed macrophages. Finally, comparative experiments on micropatterned polydimethylsiloxane (PDMS) substrates and MCF-7 cells demonstrate that the proposed method achieves equivalent average pixel rates up to 3.02 times and 1.85 times that of the conventional method, respectively, with the mean square error (MSE) on PDMS as low as 62.4% of the conventional value. These findings validate the potential of the adaptive scanning approach to overcome the scanning speed limitations of SICM, improving both imaging efficiency and quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on nonlinear spatial stitching method of SICM images based on adaptive region candidates.Ultramicroscopy · 2026
- Optical-feedback scanning ion conductance microscopy with high-speed and low-overshoot probe control.Micron (Oxford, England : 1993) · 2026
- Quantifying and Utilizing Electroosmotic Flow for Mechanical Measurements with the Scanning Ion Conductance MicroscopeAnalytical Chemistry · 2025
- Development of Scanning Ion-Conductance Microscopy Based Tip-Enhanced Raman Spectroscopy in Liquid Environments.Nanotechnology · 2026
- Advances in scanning probe microscopy for biological systems.Biophysics reports · 2026
- Perspective on Scanning Electrochemical Probe Microscopy in Single-Cell Imaging.Chemical & biomedical imaging · 2026