Subpicogram-Level Quantification of Trace Biomarkers Using an Automated High-Sensitivity Chemiluminescence Immunoassay Technology Based on a Novel Substrate Enhancement Strategy.
Kexin Li, Zhuonan Duan, Ke Li, Yanzhong Wang, Minjie Wang, Yujuan Zhang, Ruijun Tian, Changying Fu,
Department of Clinical Laboratory, State Key Laboratory of Molecular Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing100021, China. · Immunoassay Reagent R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd, Shenzhen518055, China.
Key points
From the paper's conclusion- We established an automated high-sensitivity CLIA technology based on a novel substrate enhancement strategy, improving the analytical sensitivity to the subpicogram level.
Abstract
Trace biomarkers showed great potential for improving the diagnosis and monitoring of various diseases. However, the sensitivity of the current high-throughput detection platforms is limited, posing a significant challenge for the reliable measurement and clinical application of trace biomarkers. We developed an automated high-sensitivity chemiluminescence immunoassay (CLIA) technology with subpicogram-level sensitivity based on the modification of the substrate molecular structure and the synergy of surfactant and fluorescein. Using this technology, we constructed assay kits for five trace biomarkers: leukemia inhibitory factor (LIF), high-sensitivity cardiac troponin I (hs-cTnI) and T (hs-cTnT), phosphorylated tau-217 (p-tau217), and estradiol (E2). The analytical and clinical performance was evaluated by examining the precision, linearity, limits of detection, and methodological comparison. The high-sensitivity chemiluminescent substrate demonstrated approximately 7-fold higher sensitivity and 2.5-fold greater luminescence efficiency compared to those of the traditional substrate, with a linear range exceeding 160 million relative light units (RLUs). The five trace biomarker assays exhibited excellent analytical sensitivity, with the LoD values of 0.070 pg/mL (LIF), 0.18 pg/mL (hs-cTnI), 1.1 pg/mL (hs-cTnT), 0.007 pg/mL (p-tau217), and 0.113 pg/mL (E2 II). Compared with other high-sensitivity detection methods, the Passing-Bablok linear correlation coefficients (r) ranged from 0.9767 to 0.9974. The proportions of cTnI, cTnT, and E2 II concentrations above the LoD in healthy populations exceeded 98%. We established an automated high-sensitivity CLIA technology based on a novel substrate enhancement strategy, improving the analytical sensitivity to the subpicogram level. An automated high-throughput detection method of various trace biomarkers was realized that may have broad application in the clinic.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Integrated Cartridge-Based Multiplex Chemiluminescent Immunosensor Platform for the Simultaneous Quantification of Five Coagulation and Fibrinolysis Biomarkers.Analytical chemistry · 2026
- Magnetic Rolling Circle Amplification-Assisted Automated Electrochemiluminescence Immunoassay for Ultrasensitive Determination of Protein BiomarkersAnalytical Chemistry · 2025
- Digital Microfluidic Chemiluminescence Immunoassay Cartridge for Automated Point-of-Care Protein Detection.Analytical chemistry · 2026
- Electrochemiluminescence-based multiplex immunoassays for multianalyte bioanalysis: Signal encoding strategies and analytical perspectivesElectrochemistry Communications · 2026
- Lock-in Biosensing beyond the Analog Ensemble Detection Limits.Analytical chemistry · 2026
- Lanthanide Metal-Organic Frameworks Enable Target-Triggered CRISPR-Cas12a Activator Release for Ultrasensitive Non-nucleic Acid Biomarker Detection.Analytical chemistry · 2026