Quantitative LA-ICP-MS Imaging of Elemental Distributions with Protein Correlation in 3D Tumor Models.
Fatimah Zachariah Ali, Alexander P Morrell, Piotr Robert Golda, Norfazlina Mohd Nawi, Premkamon Chaipanichkul, John M McArthur, Pascal F Durrenberger, Huda Alnufaei,
Division of Surgery and Interventional Science, Faculty of Medicine, University College London (UCL), 43-45 Foley St, LondonW1W 7TY, U.K. · London Metallomics Facility, King's College London (KCL), Franklin Wilkins Building, Stamford Street, LondonSE1 9NQ, U.K.
Key points
From the paper's conclusion- Here we establish a validated workflow for quantitative LA-ICP-MS imaging in tumor spheroids, enabling spatial correlation with immunohistochemistry using consecutive sections.
Abstract
Therapeutic efficacy in complex tissues depends on microscale drug and elemental distributions, yet quantitative mapping of these distributions in three-dimensional (3D) biological systems remains technically challenging. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) enables sensitive elemental imaging, but quantitative application in heterogeneous 3D models is limited by preparation artifacts, calibration challenges and lack of validated integration with biological markers. Here we establish a validated workflow for quantitative LA-ICP-MS imaging in tumor spheroids, enabling spatial correlation with immunohistochemistry using consecutive sections. Systematic evaluation of preparation revealed substantial analyte redistribution under conventional conditions. Optimized cryo-embedding in 2% carboxymethyl cellulose combined with freeze-drying reduced peripheral boron leaching by ∼53% compared with gelatin-based media and ∼84% compared with OCT. Matrix-matched calibration (r2 > 0.99) with endogenous 31P normalization enabled reproducible pixel-level quantification consistent with bulk ICP-MS measurements (p > 0.05). Consecutive section analysis showed protein expression varied by <20% between adjacent 30 μm sections, with radial profiles showing strong correlations across proteins and cell lines (Pearson r = 0.558-0.996), supporting spatial correlation of elemental and protein distributions. Applied to boron as a stringent low-mass analyte, the workflow achieved 10 μm spatial resolution with ∼7.4 ng g-1 detection limits. This approach provides a reproducible platform (Pearson r = 0.865-0.961, n = 3, p < 0.0001) for quantitative elemental imaging and cross modal spatial analysis in heterogeneous 3D biological systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating limits of detection for single-cell elemental bioimaging by LA-ICP-TOFMSTalanta · 2026
- Subcellular capillary sampling coupled to laser ablation – Inductively coupled plasma – Mass spectrometry (LA-ICP-MS) allows targeted analysis of thallium in a radiopharmaceutical modelSpectrochimica Acta Part B Atomic Spectroscopy · 2026
- A frozen-suspension external calibration strategy for quantitative imaging of Ce in fresh animal soft tissues by CLA-ICP-MS.Talanta · 2026
- On-Slide Preparation of Caenorhabditis elegans toward Quantitative, High-Resolution LA-ICP-TOF Mass Spectrometry Imaging.Analytical chemistry · 2026
- From visualization to mechanistic resolution: Methodological considerations for cell-mineral interactions in three-dimensional breast tumor models.Colloids and surfaces. B, Biointerfaces · 2026
- Bridging the gap between micro- and nanoscale chemical imaging of biomaterials: a multimodal and multiscale characterization framework.The Analyst · 2026