An i-Motif Conformational Transition Synergizing with pH-Responsive Reduced Graphene Oxide Field-Effect Transistor for Urease Activity Sensing.
Huan Ju, Xiangna Ni, Yanqi Tan, Zhiping Song, Xiaoping Chen, Jiancong Ni, Zhenyu Lin, Weiqiang Yang
Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Fujian Provincial Key Laboratory of Pollution Monitoring and Control, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou363000, China. · Fujian Institute of Hematology, Fujian Provincial Key Laboratory on Hematology, Fujian Medical University Union Hospital, Fuzhou350001, China.
Key points
From the paper's conclusion- In this work, we report for the first time a C4-rGO-FET biosensor by integrating a conformation-switchable C4-DNA probe with an electrochemically reduced graphene oxide field-effect transistor.
Abstract
Urease serves as a key diagnostic biomarker, whose abnormal activity is closely associated with oral diseases such as caries and periodontitis. However, detecting trace urease in saliva remains technically challenging. In this work, we report for the first time a C4-rGO-FET biosensor by integrating a conformation-switchable C4-DNA probe with an electrochemically reduced graphene oxide field-effect transistor. The sensing mechanism relies on the pH-induced conformational transition of C4-DNA between a folded i-motif and an unfolded state, which effectively modulates the interfacial charge and thus the carrier distribution in the rGO channel, resulting in a measurable shift in the Dirac point voltage (VCNP). The designed sensor exhibits significantly enhanced pH response (51.57 mV/pH) and reduces the Debye shielding effect. Upon urease-catalyzed hydrolysis of urea, the resulting local pH increase triggers a positive VCNP shift, enabling highly sensitive detection of urease activity. The biosensor demonstrates a wide linear range (1-500 U/L), a low detection limit (0.18 U/L), and good reproducibility. Moreover, it performs reliably in spiked human saliva samples, highlighting its strong potential for point-of-care testing and real-time monitoring in clinical diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A DNA-based nanosensor for in situ precise imaging of lysosomal potassium ions via pH activation.Biosensors & bioelectronics · 2026
- Ce/Zr-MOF- and TCEP-Mediated Ascorbic Acid Generation for In Situ Oxygen Vacancy Regulation in Bi4O5I2/Bi2S3 Gate: A Triple-Mode Biosensor for ALKBH5 Detection.Analytical chemistry · 2026
- Carbon Nanomaterial Field-Effect Transistor Biosensors and DNA-Based Biointerface EngineeringACS Nano · 2026
- Oxygen vacancy-tuned Bi-MOF for photoelectrochemical detection of uracil-DNA glycosylase.Talanta · 2026
- Tissue-adhesive hydrogel–MXene biosensor for in situ intraoral TNF-α detectionScience Advances · 2026
- Ultrasensitive Electrochemical Biosensor for DNA Methylation Detection Based on Fe-MOF/PANI and Catalytic Hairpin Assembly Cascade ReactionAnalytical Chemistry · 2026