CO2 Microbubble Preconcentration Coupled with Portable Mass Spectrometry for Rapid On-Site Perfluorocarboxylic Acid Quantification in Dynamic Waters.
Zhi-Yang Huang, Chuping Lee
Department of Chemistry, National Chung Hsing University, Taichung City402202, Taiwan.
Key points
From the paper's conclusion- Herein, we developed a field-deployable analytical platform integrating CO2 microbubble preconcentration and portable MS to enable the rapid quantification of perfluorocarboxylic acids (PFCAs), a major class of PFASs.
Abstract
In-situ detection is essential for pollutant source tracking and timely environmental management, particularly in dynamic water systems. However, implementing such detection remains challenging for trace organic contaminants such as per- and polyfluoroalkyl substances (PFASs) because their pg mL-1 level concentrations and complex matrix interferences often necessitate time-consuming LC-QqQ MS workflows. Herein, we developed a field-deployable analytical platform integrating CO2 microbubble preconcentration and portable MS to enable the rapid quantification of perfluorocarboxylic acids (PFCAs), a major class of PFASs. This platform leverages PFCA surface activity to drive sequential transfer from bulk water to the CO2 bubble-water interface and subsequently into bursting microdroplets, achieving >1100-fold enrichment of two common PFCAs, PFOA and PFNA, within 5 min. This enrichment may be associated with fine, slow-rising CO2 microbubbles that prolong interfacial contact and CO2-induced acidification that may favor anionic PFCA accumulation at the bubble-water interface. Based on this platform, method validation with PFOA and PFNA in drinking water revealed 80-112% recovery, high inter- and intraday precision of 3-16% RSD, and method quantification limits of 0.55-1.0 pg mL-1. Field deployment in lake and river waters successfully quantified PFOA and PFNA at concentrations of 2.4-4.1 and 0.8-1.1 pg mL-1, respectively. To our knowledge, this is one of the first portable MS/MS-based workflows capable of pg mL-1 level PFCA quantification in environmental waters. Crucially, these on-site results were consistent with conventional laboratory-based analysis, supporting this platform as a rapid (<10 min) and practical tool for dynamic environmental monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Covalent Organic Frameworks for Exceptional Removal of PFAS From WaterAngewandte Chemie · 2026
- Scalable Fluorinated Copper-Based Covalent Organic Frameworks for Coupled Ultratrace Perfluoroalkyl Substances Monitoring and Efficient Remediation.Journal of the American Chemical Society · 2026
- Covalent Organic Frameworks for Exceptional Removal of PFAS From Water.Angewandte Chemie (International ed. in English) · 2026
- Ratiometric detection of perfluoroalkyl carboxylic acids using dual fluorescent nanoparticles and a miniaturised microfluidic platformNature Communications · 2025
- Improved Py-GC/MS Analysis of Nanoplastics in Environmental Waters via Organic-Free Flocculation-Based PreconcentrationEnvironmental Science & Technology · 2026
- Targeted and Non‐Targeted Analysis of Novel and Legacy Per and Polyfluoroalkyl Substances in River Water by Direct Analysis in Real Time Mass SpectrometryRapid Communications in Mass Spectrometry · 2026