Direct Characterization of Halogen-Based Microplastics via Single-Event ICP-Mass Spectrometry in Negative-Ion Mode.
Antonio Bazo, Eduardo Bolea-Fernandez, Ana Rua-Ibarz, Martín Resano, Hamid Badiei, David Clases, Andrea Raab, Jörg Feldmann,
Department of Analytical Chemistry, Aragon Institute of Engineering Research (I3A), University of Zaragoza, 50009Zaragoza, Spain. · PerkinElmer Scientific Canada ULC, WoodbridgeL4L 8H1, Ontario, Canada.
Key points
From the paper's conclusion- Overall, this work establishes negative-ion mode single-event ICP-MS as a direct platform for fluorine- and chlorine-selective microplastic detection and sizing, expanding the analytical scope of particle-resolved microplastic analysis beyond indirect fluorine detection or carbon-based approaches.
Abstract
Halogen-containing microplastics such as polytetrafluoroethylene (PTFE) and poly(vinyl chloride) (PVC) are analytically relevant targets, yet their selective characterization by ICP-MS remains challenging, particularly for fluoropolymers due to the limited formation of F+ in conventional positive-ion mode. Here we introduce negative-ion single-event ICP-MS as a direct strategy for particle-resolved characterization of halogen-containing microplastics by monitoring F- and Cl- on a quadrupole ICP-MS without plasma modifiers or proxy-ion chemistry. PTFE and PVC particle standards were used as well-defined model systems, with scanning electron microscopy (SEM) confirming particle morphology and size distributions. Key acquisition and instrumental conditions governing event detectability were systematically optimized, enabling reliable transient detection at a dwell time of 100 μs. Using a conventional spray-chamber configuration, size detection limits of 1.18 μm (PTFE) and 0.73 μm (PVC) were achieved, improving to 0.68 μm (PTFE) and 0.45 μm (PVC) with a high-efficiency sample introduction system. Quantification strategies for negative-mode operation, including external calibration and transport-efficiency-based workflows, were further assessed. Overall, this work establishes negative-ion mode single-event ICP-MS as a direct platform for fluorine- and chlorine-selective microplastic detection and sizing, expanding the analytical scope of particle-resolved microplastic analysis beyond indirect fluorine detection or carbon-based approaches.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sizing and quantification of micro- and nanoplastics by single particle ICP-MS: a comparison between quadrupole and high-resolution instruments.Frontiers in chemistry · 2026
- Single-Particle Microplastics Analysis via Laser-Assisted MicroPyrolysis Flowing Atmospheric-Pressure Afterglow Mass Spectrometry Imaging.Analytical chemistry · 2026
- Multimodal Single-Particle Characterization of Airborne Microplastics Reveals Physicochemical Heterogeneity and Aging-Related Features.Analytical chemistry · 2026
- Solvent-Free Bubbling Extraction Mass Spectrometry for Ultrasensitive, Size-Independent Detection of Microplastics in Water.Analytical chemistry · 2026
- Identification of Microplastics by Calcined Sand Assisted Ambient Laser Desorption Electrospray Ionization Mass Spectrometry.Analytical chemistry · 2026
- Raman-validated image learning enables microplastic prescreening and electronic-waste candidate prioritizationnpj Clean Water · 2026