Evaluation of the Global Fibrinolytic Capacity of Whole Blood
Liming Liu, Jiale Gao, Xiaoling Zheng, Bo Zhang, Huijun Liu, Yi-Zhen Wan, Tianze Wang, Yuxin Zhai,
Key points
From the paper's conclusion- Here, we constructed a fibrin clot exhibiting optical interference effects as a fibrinolysis model, and introduced an ordered porous layer interferometry (OPLI) technique for real-time, in situ monitoring of the global fibrinolytic capacity of whole blood.
Abstract
Assessment of the global fibrinolytic capacity of whole blood is of great clinical value for the diagnosis of bleeding and thrombotic disorders, the guidance of therapeutic decision-making, and prognosis monitoring. However, due to the complexity of the fibrinolytic system, existing fibrinolysis assays fail to meet clinical diagnostic requirements, and it remains challenging to design a “gold standard” analytical method that can reflect the global fibrinolysis level of blood. Here, we constructed a fibrin clot exhibiting optical interference effects as a fibrinolysis model, and introduced an ordered porous layer interferometry (OPLI) technique for real-time, in situ monitoring of the global fibrinolytic capacity of whole blood. We equated the global fibrinolytic capacity to plasmin activity while effectively suppressing non-specific adsorption under dynamic blood-flow conditions, thereby enabling accurate quantitative evaluation. The developed method was applied to monitor the dose-dependent downregulating effects of the endogenous fibrinolytic inhibitors PAI-1 and α2-AP on whole blood global fibrinolytic activity. Furthermore, this method successfully differentiated and quantified the ranges of global fibrinolytic capacity among hypofibrinolysis, normal fibrinolysis, and hyperfibrinolysis phenotypes. The analytical results showed a strong correlation with corresponding clinical bleeding and thrombosis risk scores. A parallel comparison with the thromboelastography method further validated the clinical applicability of this method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-Time and Rapid Fibrinolysis Analysis Based on Fibrin-Loaded Tubular SiO2-TiO2 Hybrid Inverse Opal.Analytical chemistry · 2026
- Dual impairment of thrombotic and fibrinolytic pathways assessed by the global thrombosis test predicts adverse clinical outcomes after percutaneous coronary interventionEuropean Heart Journal · 2026
- A-231 Tri-Modal Detection in Coagulation Testing: Performance Evaluation of the Zybio EXT 9800 Coagulation Analyzer and Its Utility in Challenging Clinical SamplesClinical Chemistry · 2026
- Investigating Fibrinolysis Resistance in Sepsis Using High‐Multiplex Plasma Proteomics: A Statistical Analysis PlanActa Anaesthesiologica Scandinavica · 2026
- Thrombin Generation Assays: Possibilities and LimitationsHämostaseologie · 2026
- Circular validation in diagnostic research: re-examination of a widely cited study on primary hemostasis screening.Frontiers in medicine · 2026