Label-Free Fluorometric Split Aptasensor for the Specific Detection of Uric Acid from Xanthine and Hypoxanthine
Jiageng Cheng, Longjiao Zhu, Yuan Su, Xinyue Lan, Zaihui Du, Y Zhang, Zhihong Liang, Wentao Xu
Center for Food Safety and Applied Nutrition · Ministry of Education
Key points
From the paper's conclusion- Finally, we developed a label-free fluorometric split aptasensor based on Apt2-T4-T3/Apt2-T5, which achieved a detection limit of 0.60 μM and exhibited a strong linear response within the UA concentration range of 3.15–200 μM.
Abstract
Xanthine and hypoxanthine are metabolic precursors of uric acid (UA), and their molecular structures and chemical properties are similar to those of UA. Consequently, accurately distinguishing between them has long posed a substantial challenge. In this study, library immobilization was employed to screen for aptamers for UA. An aptamer designated Apt2 exhibits a dissociation constant ( K d ) of 14.11 μM for UA, demonstrating low affinity for xanthine and negligible affinity for hypoxanthine. DG10 and DG11 are critical sites for maintaining its affinity and selectivity. Microscale thermophoresis (MST) analysis yielded a K d value of 461 nM for Apt2, while circular dichroism (CD) spectroscopy indicated that Apt2 might adopt a parallel G-quadruplex conformation. Based on its conserved sequence and secondary structure, Apt2 was systematically split and tailored to generate two split aptamers: Apt2-T4/Apt-T5 and Apt2-T4-T3/Apt2-T5. The K d values of these split aptamers, as measured by thioflavin T (ThT) fluorescence, were 48.78 μM and 38.72 μM, respectively. To facilitate sensor development, the kinetic and thermodynamic characteristics of these aptamers were evaluated. The results indicated that Apt2-T4-T3/Apt2-T5 binds rapidly to UA, and the melting temperature (Tm) of Apt2-T4-T3/Apt2-T5 was determined to be 40.48 ± 0.18 °C. Finally, we developed a label-free fluorometric split aptasensor based on Apt2-T4-T3/Apt2-T5, which achieved a detection limit of 0.60 μM and exhibited a strong linear response within the UA concentration range of 3.15–200 μM. Subsequently, the aptasensor was applied to detect UA in real urine samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Combining G-Quadruplex and Non-Quadruplex Aptamers with Distinct Thermodynamic Driving Forces for Highly Selective Pb2+ DetectionACS Sensors · 2026
- Photoaffinity Electrophoretic Mobility Shift Assay for Analyzing the Binding Specificity of DNA Aptamers to α-ThrombinChemical and Pharmaceutical Bulletin · 2026
- Hydnocarpin as a Potent Xanthine Oxidase Inhibitor from Hydnocarpus anthelmintica: Affinity-Guided Identification and Kinetic Characterization.Pharmaceuticals (Basel, Switzerland) · 2026
- From Cross-Reactivity to Specificity: A SELEX-Derived Aptamer Sensor Array for Aristolochic Acid I and Aristolactam I.Analytical chemistry · 2026
- Comparative Aptamer Discovery Providing Insights into Functional-Group Effects on the Recognition of Serotonin-Pathway Analytes.Analytical chemistry · 2026
- Structural Basis and Conformational Switching of Capture-SELEX Aptamers for Designing Equol Sensors.ACS omega · 2026