Analytical chemistry

Tailing-Actuated Interfacial Liquid Mixing (TAIL-Mix) Enables Efficient Nucleic Acid Extraction and Integrated HPV Genotyping on a Digital Microfluidics Platform.

Jiajian Ji, Xinpei Pang, Jinxin Fu, Maolin Zhang, Kai Jin, Hanbin Ma, Ruhong Yan, Siyi Hu,

School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei230026, China. · Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences , Suzhou215163, China.

Key points

From the paper's conclusion
  • Here we present an active-matrix digital microfluidic (AM-DMF) platform for high-throughput HPV genotyping, utilizing a tailing-actuated interfacial liquid mixing (TAIL-Mix) strategy to enable highly efficient nucleic acid extraction and robust downstream amplification.

Abstract

High-risk human papillomavirus (HPV) genotyping is essential for risk-stratified cervical cancer screening. However, current laboratory workflows remain multistep, instrument-intensive, and difficult to scale up for high-throughput multiplex testing. Here we present an active-matrix digital microfluidic (AM-DMF) platform for high-throughput HPV genotyping, utilizing a tailing-actuated interfacial liquid mixing (TAIL-Mix) strategy to enable highly efficient nucleic acid extraction and robust downstream amplification. The AM-DMF chip features a 921,600-electrode array that uses programmable, time-sequenced electrode actuation to stretch and retract droplets. This mechanism generates TAIL-Mix, significantly enhancing mixing efficiency under low-Reynolds-number conditions. Through combined COMSOL simulations and OpenCV-based image analysis, we determined that optimal TAIL-Mix parameters (a tailing distance of 7-8 pixels; 1.5 steps s-1) achieve a homogeneous state (mixing index ≥ 0.9) within 2 s, superior to traditional schemes. This enhanced mixing proved to be critical for high-performance processing, enabling magnetic-bead DNA extraction with 75% DNA recovery while reducing the protocol time to 26 min and the sample input to 1.5 μL of sample (100-fold reduction compared with conventional protocols). By integrating TAIL-Mix-enhanced extraction, thermal cycling, and 21-plex end point fluorescence readout on a single chip, the platform successfully performs parallel 21-genotype PCR analysis for two samples. In a clinical cohort of 20 cervical samples, the AM-DMF assay shows 100% sensitivity and 100% specificity relative to qPCR. Ultimately, this TAIL-Mix-empowered AM-DMF system offers a robust solution for low-reagent consumption, high-throughput clinical diagnostics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers