pH-Responsive 1,8-Naphthalimide Probe for a One-Step Loop-Mediated Isothermal Amplification Assay
Kun Yan, Lidan Tang, Hufeng Fang, Hao Yang, Jie Ren, Dan Su
Soochow University · Changzhou University
Key points
From the paper's conclusion- Using this probe, we achieved a highly sensitive and specific one-step detection on lambda DNA and Escherichia coli O157:H7 through either visual inspection or quantitative real-time fluorescence monitoring.
Abstract
Loop-mediated isothermal amplification (LAMP) has garnered significant interest as a promising technique for nucleic acid testing, especially in point-of-care and on-site applications, due to its rapid assay speed and simple operating conditions. However, the wide adoption and acceptance of LAMP technology remain a challenge, primarily due to the insufficient sensitivity, poor stability, and strong subjectivity in the interpreting color transition stage. To address these, we developed a novel fluorescent probe, namely, FC-NAPH-PZ, for the LAMP assay. Its high Stokes shift and excellent pH reversibility generated a large and stable fluorescence “turn-on” signal, enabling the highly sensitive (single-copy) and ultrahigh selective detection in the LAMP assay. Meanwhile, its high stability minimized interference with efficient amplification in closed-tube LAMP. Using this probe, we achieved a highly sensitive and specific one-step detection on lambda DNA and Escherichia coli O157:H7 through either visual inspection or quantitative real-time fluorescence monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A novel double-stranded probe minimizes false-positive and false-negative LAMP results with ultrasensitivity and high specificity.The Analyst · 2026
- Smartphone-Controlled Point-of-Care Testing Platform Integrating FTA Card-Based Sample Preparation and Colorimetric LAMP for Pathogen DetectionMicromachines · 2026
- Plasmon-Enhanced Fluorescence Lateral Flow Assay Using Silica-Spaced Ag@SiO2@RuBpy Nanoprobes for Ultrasensitive and Dual-Mode Procalcitonin Detection.Analytical chemistry · 2026
- Aptamer-functionalized silver nanoparticle pre-analytical enrichment integrated with loop-mediated isothermal amplification for improved detection of pathogenic Leptospira interrogans.Journal of microbiological methods · 2026
- Rapid and Sensitive Pathogen Detection and Viability Evaluation: A Lateral Flow Assay Based on One-to-Multiple Signal AmplificationAnalytical Chemistry · 2026
- Electricity Free LAMP: A Protocol for Loop-Mediated Isothermal Amplification Using an Exothermic Chemical Reaction and Lyophilized ReagentsmedRxiv · 2026