Lysosome-Targeted Dual-Functional Probe Capable of Detecting Acute Kidney Injury via In Vivo Imaging and Urinary Albumin Detection
Siyu Jiang, B J Dai, Guoqiang Feng
Central China Normal University
Key points
From the paper's conclusion- These findings suggest that MDSM-L, as a dual-responsive fluorescent probe for albumin and viscosity, offers a novel diagnostic tool for drug-induced AKI.
Abstract
Drug-induced acute kidney injury (AKI) emerged as a pressing global health concern, necessitating the urgent development of sensitive, in situ, in vivo detection methods. Fluorescent probes demonstrated attractive advantages in disease diagnosis, particularly dual-target responsive fluorescent probes that provide superior reliability. This paper presents a lysosome-targeted dual-functional fluorescent probe, MDSM-L, suitable for quantitative detection of serum/urine albumin and real-time in vivo detection of drug-induced AKI. MDSM-L exhibits sensitive fluorescence activation characteristics for serum albumin and viscosity at 675 and 710 nm, respectively, enabling successful fluorescence detection of BSA and lysosomal viscosity changes in living cells. Notably, this probe can specifically target the kidney and has been successfully employed for the quantitative analysis of serum/urine albumin in an AKI mouse model and in vivo imaging of the kidneys. Experimental results reveal that during AKI, the albumin content in the serum slightly decreases, while the albumin content in urine significantly increases. Concurrently, the lysosomal viscosity within kidney tissue escalates. These findings suggest that MDSM-L, as a dual-responsive fluorescent probe for albumin and viscosity, offers a novel diagnostic tool for drug-induced AKI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Activatable fluorescent ratiometric probes for early diagnosis and prognostic assessment of acute kidney injuryScience Advances · 2025
- Unimolecular dual-reporter probes for early kidney injury diagnosis through synchronous in situ imaging and portable urinalysis.National science review · 2026
- Pathology-Responsive Nanoprobes for NIR-II Imaging of Acute Kidney InjuryAnalytical Chemistry · 2026
- Self-Amplified Activatable Fluorescent Probe for Early Diagnosis of Acute Kidney Injury and High-Throughput Screening of Natural Protectants.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- A Self-Alarming Nanoantidote for Early Urinary Diagnosis and Antioxidative Therapy of Drug-Induced Acute Kidney InjuryACS Nano · 2026
- Zeolite Nanoreactor Boosted Early Diagnosis of Acute Kidney Injury through a Multifunctional Biosensing Platform.Analytical chemistry · 2026