Analytical ChemistryOpen accessElectrochemiluminescence

All-Optical Electrochemiluminescence by Light Downconversion at BiVO₄ Photoanodes

Xiaodan Gou, Changlin Zhou, Jun‐Jie Zhu, Gabriel Loget, Nešo Šojić

State Key Laboratory of Chemical Engineering · Centre National de la Recherche Scientifique

Key points

From the paper's conclusion
  • Here, we report for the first time an AO-ECL downconversion process (e.g., λ exc < λ AO-ECL ) based on a bismuth vanadate (BiVO 4 ) electrode with the model luminol–H 2 O 2 system.

Abstract

Electrochemiluminescence (ECL) is a powerful analytical technique. However, the necessity of an external power supply limits its use for portable sensing devices. Herein, we report a new sensing scheme based on an all-optical ECL (AO-ECL), which addresses this issue by emitting light without external electrical devices but through light excitation (λ exc ). In AO-ECL, the photovoltage generated by the semiconductor simultaneously drives the anodic ECL reaction (producing photons at λ AO-ECL ) and a cathodic charge transfer. While this approach significantly reduces the complexity of ECL instrumentation, current materials for such systems often suffer from relatively complex fabrication methods and all existing AO-ECL systems are upconversion systems (e.g., λ exc > λ AO-ECL ). Here, we report for the first time an AO-ECL downconversion process (e.g., λ exc < λ AO-ECL ) based on a bismuth vanadate (BiVO 4 ) electrode with the model luminol–H 2 O 2 system. Because BiVO 4 has a wide absorption below 500 nm, the ECL emission spectrum further red-shifts to 510 nm. The strong responsiveness toward H 2 O 2 of the BiVO 4 AO-ECL system enables a significant shift on ECL onset potential from +0.3 V to −0.3 V (vs Ag/AgCl). A nearly 2.6-fold enhancement in ECL intensity was achieved at 0.4 V and the distinct ECL signal is observed even without applied bias. Moreover, the platform enabled cadmium ion (Cd 2+ ) detection, with the AO-ECL intensity rising 2.2-fold. The simplicity of BiVO 4 electrode fabrication combined with its cost-effectiveness positions this downconversion AO-ECL system as a potential candidate for the development of portable bioanalytical sensors and wireless bioimaging applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

All-Optical Electrochemiluminescence by Light Downconversion at BiVO₄ Photoanodes — Science Skim