From the paper's conclusion- Here, we present a novel paper-based colorimetric sensor array that leverages deep eutectic solvents (DES) and pH indicators to detect lung-cancer-specific volatile organic compounds (VOCs) in exhaled breath.
Abstract
Lung cancer remains the leading cause of cancer-related mortality worldwide, primarily due to the lack of accessible, noninvasive early diagnostic tools. Here, we present a novel paper-based colorimetric sensor array that leverages deep eutectic solvents (DES) and pH indicators to detect lung-cancer-specific volatile organic compounds (VOCs) in exhaled breath. The hydrophobic DES enhances sensor stability and selectivity by mitigating moisture interference, while amplifying VOC interactions through hydrogen bonding and proton exchange. Breath samples from 91 participants (46 lung cancer patients, 28 noncancer respiratory disease patients, and 17 healthy controls) were analyzed using a portable, sterilized collection system. The sensor array achieved 93% accuracy in discriminating cancer patients from noncancerous individuals via linear discriminant analysis (LDA), with 98% sensitivity and specificity at the optimal cutoff. Notably, the system also distinguished lung cancer from other respiratory diseases (87% accuracy), addressing a critical clinical challenge. Hierarchical cluster analysis (HCA) and ROC curves further validated the robustness of the platform. This cost-effective, rapid, and noninvasive approach demonstrates significant potential for large-scale lung cancer screening, offering a transformative alternative to conventional diagnostic methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Point-of-Care Breath Volatile Organic Compound Analysis as a Tool for Lung Cancer Screening: A Pilot Feasibility Study.medRxiv : the preprint server for health sciences · 2026
- Clinical Diagnosis of Lung Cancer via Exhaled Breath Analysis Using an Ultrasensitive and Cross-Selective Benzene-Derivative Gas Sensor Assisted by Machine LearningACS Sensors · 2026
- Ultrasensitive Breath Analysis of Lung Cancer Biomarkers Using a Carboxyl-Functionalized Hyper-cross-linked Polymer-Based SPME Coupled with GC─MS.Analytical chemistry · 2026
- Breathomics Analysis for Early Diagnosis of Lung Cancer Based on PTR ‐ TOF MS : A Large Sample Size Cross‐Sectional StudyRespirology · 2026
- Ensemble-learning-assisted exhaled gas disease analysis based on in-situ construction of MOF-derived MOx/GaN heterojunction sensor arraysMicrosystems & Nanoengineering · 2026
- Exhaled Breath Analysis for Lung Cancer Detection: From VOCs Signatures to EBC-Based Liquid Biopsy and Clinical Translation.Thoracic cancer · 2026