Impedance soft stops for powered knee orthoses: A pilot study of gain-scheduled PD flexion limitation in healthy adults
Marc-Anton Scheidl, Kristin Schuh, Oguzhan Uzun, Marcel Betsch, Claudio Castellini
Key points
From the paper's conclusion- We developed a software-defined impedance soft stop for powered knee orthoses, implemented as a gain-scheduled proportional-derivative controller that increases stiffness and damping near a prescribed flexion boundary with angle- and velocity-gated engagement.
Abstract
After anterior cruciate ligament reconstruction, adjustable braces commonly restrict knee range of motion using rigid flexion stops, which can produce abrupt impacts and discomfort. Passive compliant mechanisms remain hardware-dependent. We developed a software-defined impedance soft stop for powered knee orthoses, implemented as a gain-scheduled proportional-derivative controller that increases stiffness and damping near a prescribed flexion boundary with angle- and velocity-gated engagement. We conducted a counterbalanced six-condition crossover pilot study (physiological gait, orthosis only, orthosis plus motor with the soft stop disabled, rigid stop, firm soft stop, and mild soft stop) with n = 8 $ n=8 $ n equals 8 healthy adults walking at 3 km/h. Outcomes included knee kinematics from the actuator encoder and optical motion capture, actuator torque and compensatory kinematics, and eight-channel surface electromyography (sEMG). Relative to the motor-only condition, soft stops reduced swing-phase knee flexion ( q 95 $ {q}_{95} $ q 95 ) from 61.1 ∘ $ {61.1}^{\circ } $ 61.1 ring [58.4, 63.8] to 37.1 ∘ $ {37.1}^{\circ } $ 37.1 ring [36.4, 37.8] (firm) and 44.6 ∘ $ {44.6}^{\circ } $ 44.6 ring [43.4, 45.8] (mild), and reduced flexion velocity from 3.63 $ 3.63 $ 3.63 to 1.02 $ 1.02 $ 1.02 – 1.47 rad / s $ 1.47\;\mathrm{rad}/\mathrm{s} $ 1.47 rad slash s . Mean resisting torques remained modest ( 2.64 N m $ 2.64\;\mathrm{N}\;\mathrm{m} $ 2.64 Nm firm, 1.65 N m $ 1.65\;\mathrm{N}\;\mathrm{m} $ 1.65 Nm mild), and compensatory kinematic changes were generally small. During terminal swing, the analysis identified higher right-biceps-femoris average rectified value with the rigid stop than with both orthosis baselines and both soft-stop conditions. Angle- and velocity-gated impedance soft stops provided effective software-defined flexion limitation in a powered knee orthosis while keeping torque demands low and avoiding increased biceps femoris activation and perceived burden associated with rigid stops. Clinical performance after ACL reconstruction remains to be evaluated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Crossing Obstacles during Walking through Self-adaptive Volitional Control of a Powered Knee Prosthesis.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- An Active Knee–Ankle–Foot Orthosis With Torque‐Dense, Low‐Impedance Knee ActuationAdvanced Intelligent Systems · 2026
- The variable stiffness orthosis: customizable mechanics for assistance and rehabilitationJournal of NeuroEngineering and Rehabilitation · 2026
- An Adaptive Knee Brace Is Associated With Improved Dynamic Stabilization Compared With a Standard Passive Brace in Anterior Cruciate Ligament-Deficient Men During a Functional Hop Task.Arthroscopy, sports medicine, and rehabilitation · 2026
- Biomechanical Trade-Offs in Knee Brace Stiffness: Dynamic Stability During Single-Leg Lateral Landings in Young MalesIEEE Transactions on Neural Systems and Rehabilitation Engineering · 2026
- Effects of ankle-foot orthosis stiffness on lower-limb joint work during various movement tasks in people with calf muscle weakness-an explorative study.Frontiers in rehabilitation sciences · 2026