Analysis of regular and small samples at Tandem Laboratory, Uppsala University: 10 years of operation using a MICADAS
Melanie Mucke, Maximilian Rughöft, Jonas Balkefors, Karl Håkansson, Daniel Primetzhofer
Key points
From the paper's conclusion- We report on 10 years of operation of a MICADAS compact tandem accelerator for radiocarbon ( 14 C) analysis at the Tandem Laboratory national research infrastructure at Uppsala University comprising analysis of over 40,000 samples.
Abstract
We report on 10 years of operation of a MICADAS compact tandem accelerator for radiocarbon ( 14 C) analysis at the Tandem Laboratory national research infrastructure at Uppsala University comprising analysis of over 40,000 samples. Based on the large number of analyzed samples and associated references, we perform an analysis of the target scatter of employed IAEA-C7 and SRM-4990C-standards. As a result, we show how the target scatter deduced from a single magazine run is falling below the long-term statistical average, which can result in a systematic uncertainty in 14 C results obtained from such runs. We also discuss effects of sample size on current and potential corrections for contamination or non-linearities in the measurement for standard samples spanning a wide range of activity levels, down to below 10 µg C equivalent. Finally, we discuss an observed mass dependence of stable isotope ratios in IRMS, which, if not measured by the accelerator itself, could impact 14 C determination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Status report: The first three years of MICADAS operation at AEL-AMS National Facility, Ottawa, CanadaRadiocarbon · 2026
- Radiocarbon analysis on the new 1 MV multi-element BNUAMS systemRadiocarbon · 2026
- Four decades of actinide (U, Th, Pu, Am) analysis in environmental samples (1986-2026): evolution of measurement, detection and quantification, with a multivariate bibliometric assessment.Journal of environmental radioactivity · 2026
- Determination of stable carbon isotope ratios for molecules in natural organic matter using ESI FT-ICR MSScience Advances · 2026
- Interlaboratory comparison of bio-based carbon content in disposable packaging samples from PakistanRadiocarbon · 2026
- An Easy and Reliable Method for Calibrating Combustion-Based Total Organic Carbon Analyzers for Solid Samples Containing Less than 100 μg of Carbon Using Polystyrene Microspheres.Analytical chemistry · 2026