Frequency synchronisation and modal mapping of wake dynamics to the performance of a vertical-axis turbine
Ruiwen Zhao, Fang Chen, Angus C.W. Creech, Zhiliang Lin, Yao Yue, Alistair G.L. Borthwick
Key points
From the paper's conclusion- These findings bridge the gap between instantaneous flow topologies and global performance metrics, and provide a rigorous physical foundation for real-time diagnostics and optimisation of tidal energy conversion systems.
Abstract
The transition towards sustainable marine energy relies partly on efficient deployment of vertical-axis tidal turbines, yet their widespread application is constrained by the complex, unsteady fluid dynamics inherent in their operation. While vertical-axis turbines offer superior structural scalability, they experience intricate vortex shedding and wake-induced energy losses which can make performance difficult to predict accurately. We address this critical gap by establishing a novel, data-driven quantitative correlation between wake characteristics and hydrodynamic performance. A high-fidelity actuator line model within a large eddy simulation framework is used to simulate the three-dimensional dynamic response of a vertical-axis tidal turbine in unsteady flow. Proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) reveal that the wake is governed by prominent low-dimensional dynamics, with primary POD modes capturing over 60 percent sign 60 % $60\,\%$ of the fluctuating energy. The dominant DMD mode corresponds to the fundamental blade rotation frequency, while a critical frequency shift in a secondary shedding mode ( italic St equals 1.477 St = 1.477 $\textit{St} = 1.477$ ) is identified, elucidating the complex coupling between dynamic stall vortices and shear layer instabilities. By integrating reduced-order DMD-based modelling with a physics-inspired symbolic regression framework, we establish the first explicit mathematical mapping between pivotal modal descriptors (including energy fraction, decay rate and frequency) and the power coefficient upper C Subscript upper P C P $C_{\!P}$ . The resulting model demonstrates that power extraction at this optimal condition is governed primarily by frequency synchronisation among low-frequency coherent structures, achieving zero fitting error at the design point. These findings bridge the gap between instantaneous flow topologies and global performance metrics, and provide a rigorous physical foundation for real-time diagnostics and optimisation of tidal energy conversion systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross-scale aerodynamics and wake coherent structures of vertical-axis wind turbines via data-driven modal decompositionPhysics of Fluids · 2026
- Large-eddy simulation of power and wake responses of a tidal stream turbine under prescribed floating-platform motionsPhysics of Fluids · 2026
- Aerodynamic-aeroacoustic co-design and multi-objective optimization of vertical-axis wind turbines: a critical review of dynamic stall, flow control, and data-driven methodsFrontiers in Mechanical Engineering · 2026
- Numerical simulation of vortex-induced vibration response of a single IEA 10-MW wind turbine bladeJournal of Fluids and Structures · 2026
- Vortex interactions in the near wake of a pile-supported horizontal axis tidal stream turbineApplied Ocean Research · 2025
- Development and validation of an improved double-multiple streamtube model for predicting performance of H-type straight-bladed vertical axis wind turbinesPhysics of Fluids · 2026