Assessment of commercially available constant voltage head-only electrical stunning systems for turkeys
Troy J. Gibson, Carlos B. Rebelo, Natalie Chancellor, Safiyyah Goollam Kader, Siobhan M. Abeyesinghe
Key points
From the paper's conclusion- This study aimed to evaluate these systems through: (1) a survey of slaughter practices used by small-scale UK producer/processors; and (2) an experimental assessment of stunning effectiveness in turkeys ( Meleagris gallopavo domesticus ) using the three most commonly reported head-only electrode configurations.
Abstract
There is limited information on the slaughter systems employed by small-scale poultry producer/processors in the UK. This study aimed to evaluate these systems through: (1) a survey of slaughter practices used by small-scale UK producer/processors; and (2) an experimental assessment of stunning effectiveness in turkeys ( Meleagris gallopavo domesticus ) using the three most commonly reported head-only electrode configurations. A survey of 20 poultry and waterfowl producer/processors revealed substantial variation in stunning equipment, electrode design and reported electrical parameters. Constant-voltage systems predominated, and many respondents were unable to report the current, voltage or frequency used. Four producer/processors reported operating below the legal minimum current for turkeys (400 mA), and a range of electrode types was identified, with the three most reported tested in the experimental study. In the experimental study, 39 ex-breeding turkeys were stunned with a commercially available constant voltage (50 Hz AC sinusoidal waveform) head-only electrical stunner using single-pin, needle-pin or three-pin electrodes. Stunning effectiveness was assessed using recorded electrical parameters, current profiles, behavioural and brainstem indicators, and time to return of visual evoked potentials (VEPs). Needle-pin and three-pin electrodes produced higher peak currents and shorter times to peak current than single-pin electrodes. VEPs were initially abolished immediately after all stuns but returned earliest with single pin (12.0 [± 2.7] s, range: 5.4–24.0 s), and needle pin electrodes (15.0 [± 2.6] s, range: 4.8–35.4 s). Return of VEPs was delayed significantly longest with three-pin electrodes (26.0 [± 2.6] s, range: 13.8–52.8 s) compared to the other electrode types. There was no significant difference between treatments in time to return of rhythmic breathing or nictitating membrane reflexes. In conclusion, these findings suggest that constant-voltage head-only stunning systems may not reliably prevent recovery before or during exsanguination, although three-pin electrodes performed better than the alternatives.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Part 2: Behavioural and electroencephalographic assessment of upright restraint and head-only electrical stunning of broilersAnimal Welfare · 2026
- Part 1: Assessment of upright restraint of broilers for head-only electrical stunningAnimal Welfare · 2026
- Assessment of on-farm euthanasia methods for pigs weighing 2 to 25 kg.Journal of animal science · 2026
- Electrical Stunning does not affect Brain Tissue Integrity and Stress Response in Larval ZebrafishbioRxiv · 2026
- Assessment of USDA FSIS Humane Handling Enforcement Actions: 2021-2023Translational Animal Science · 2026
- Impact of controlled atmosphere and electrical stunning coupled with water immersion and air chilling on breast fillets and thighs during retail display storage.Poultry science · 2026