Journal of pharmaceutical sciences

Polysorbate-based mixed micelles for protein stabilization: Development of manufacturing methods for phosphatidylcholine-polysorbate 80 systems and comparison to polysorbate 20 systems.

Johanna Weber, Lukas Bollenbach, Tim Diederichs, Patrick Garidel, Karsten Mäder

Martin Luther University Halle-Wittenberg, Institute of Pharmacy, Faculty of Biosciences, Halle (Saale), Germany. · Martin Luther University Halle-Wittenberg, Institute of Pharmacy, Faculty of Biosciences, Halle (Saale), Germany; Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, TIP, Biberach an der Riss, Germany.

Key points

From the paper's conclusion
  • We first established and characterised a preparation protocol for PS80 mixed micelles.

Abstract

Surfactants are commonly employed in protein formulations because proteins can undergo denaturation and particle formation. In the domain of pharmaceuticals, polysorbates (PS) such as PS20 and PS80 are extensively used as non-ionic surfactants in pharmaceutical formulations. However, polysorbates themselves may contribute to formulation instabilities, motivating efforts to reduce their concentration. In our recent work, the properties of mixed micelles of PS20 with a phospholipid as a stabilising excipient for protein formulations were characterised, in which part of the PS was substituted by a phospholipid. In this study, we examine the stability of mixed micelles of PS80 in the presence of hydrogenated soybean phosphatidylcholine, a potential protein-stabilising system. We first established and characterised a preparation protocol for PS80 mixed micelles. Subsequently, an evaluation was conducted of their protein-stabilising properties in shaking studies on a monoclonal antibody to assess colloidal stability under stress. Visual inspection and particle analysis were applied to monitor particle formation, and size-exclusion chromatography was used to monitor high molecular weight species. In the third step of the research, the stabilising properties of both PS80 and PS20 mixed micelle systems were assessed across the tested concentration range (0.004-0.4 mg·mL-1). This was accompanied by a direct comparison with the corresponding polysorbates. Transmission and dynamic light scattering indicated that mixed micelles were obtained at concentrations reaching 20 mg·mL-1 and phospholipid fractions around 50 %. In the context of shaking studies conducted on a monoclonal antibody, the presence of mixed micelles was found to be associated with a reduction in the formation of particles and high molecular weight species. The performance of the mixed micelles was found to be comparable to that of the polysorbates with respect to the endpoints measured under the conditions tested.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Polysorbate-based mixed micelles for protein stabilization: Development of manufacturing methods for phosphatidylcholine-polysorbate 80 systems and comparison to polysorbate 20 systems — Science Skim