Journal of pharmaceutical sciences

Preferential API loss during dry granulation milling for ribbons containing high concentration of polyethylene oxide.

Stephen Ma, Hansol Lee, Niki Abbasi, Audrey Sickles, Ashish Punia, Thomas Morrow, Cheng Sun, William Rappa,

Merck & Co., Inc., 126 E Lincoln Ave Rahway, NJ, USA. Electronic address: stephen.ma@merck.com. · Merck & Co., Inc., 126 E Lincoln Ave Rahway, NJ, USA.

Key points

From the paper's conclusion
  • In addition, remediations for assay loss are proposed for dry-granulating polyethylene oxide formulations.

Abstract

This study evaluated API loss during dry granulation of push-pull osmotic tablet active layer formulations. Two formulations, one containing polyethylene oxide, mannitol, and API, and another containing only polyethylene oxide and API, were roller compacted to form the active layer of the bilayer tablet. Unacceptable API loss and processability issues were observed between dry granulation and compression for mannitol-free formulations across multiple campaigns, roll forces, batch sizes and drug loads. Two hypotheses were investigated further: mannitol-API interactions that increase API retention in the mannitol-containing formulations, or the difficulty of impact-milling a highly concentrated, ductile-polymer-based formulation. In addition, remediations for assay loss are proposed for dry-granulating polyethylene oxide formulations.