Optical coherence tomography as a process analytical technology for oral film formulations.
Leonie-Lara Dorothea Uth, Matthias Wolfgang, Stefan Klinken-Uth, Johannes Khinast, Joerg Breitkreutz
Institute of Pharmaceutics and Biopharmaceutics, Faculty of Mathematics and Natural Sciences, Heinrich Heine University, Universitätsstraße 1, Düsseldorf, Germany. · Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, Graz, Austria.
Key points
From the paper's conclusion- The main obstacles to the use of OCT as an inline Process Analytical Technology in continuous oral film manufacturing therefore lie in system integration, i.e. mechanical film guidance, automated onboard evaluation and image retention, rather than in the optical performance of the instruments.
Abstract
In oral film manufacturing, the dose of the active pharmaceutical ingredient is set by cutting the cast film into portions of defined area, which makes film thickness a critical quality attribute and an attractive target for calibration-free in-process measurement. This study evaluated Optical Coherence Tomography (OCT) to monitor film thickness of oral films along the offline-to-inline continuum. A galvanometer-scanning spectral-domain OCT system, acquiring full two-dimensional cross-sections, was applied offline to cast films and inline above the moving, dried film of a continuous coating line. An OSeeT Pharma 1D sensor, which acquires depth profiles at a fixed lateral position and evaluates the interfaces within the instrument, was operated on a custom-built conveying bench reproducing continuous film movement. Offline, OCT resolved internal defects, including air bubbles, insoluble inclusions and the interlayer boundary of bilayer films. Preliminary observations further indicated its potential to detect storage-related microstructural changes. OCT consistently yielded higher thickness values than a manually operated micrometer screw, with potential contributing factors, including film compression during contact measurement and the assumption of a constant refractive index, being discussed. Inline, thickness variations induced by deliberate variation of pump rate, coating knife height and liner speed were resolved for three different polymeric film formers, with thickness values extracted by post-processing of the recorded cross-sections, although evaluable frames were lost wherever the moving film left the set focal range. The OSeeT sensor returned stable thickness, roughness and homogeneity along the entire film length and reproduced the same systematic offset against the micrometer screw reference, delivering these values continuously and without post-processing. Structural information therefore remains available alongside continuous monitoring if the acquisition is configured to retain it. The main obstacles to the use of OCT as an inline Process Analytical Technology in continuous oral film manufacturing therefore lie in system integration, i.e. mechanical film guidance, automated onboard evaluation and image retention, rather than in the optical performance of the instruments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical Coherence Tomography for High‐Precision Industrial Inspection in Industry 4.0: Advances, Challenges, and Future TrendsLaser & Photonics Review · 2025
- Spatially resolving multiple layer thicknesses in thin films with an optical in-line roll-to-roll characterization setup.Optics express · 2026
- Prediction of oxide coating thickness on moving polymer films using quantum cascade laser spectroscopy and machine learningMeasurement Science and Technology · 2026
- Volumetric imaging of Young's modulus and nonlinear elasticity on the micro-scale.Acta biomaterialia · 2026
- Optical Coherence Tomography for Quantitative Point-of-Care Ear Imaging.The Laryngoscope · 2026
- Advances in the application of optical coherence elastography in ophthalmologyJournal of Innovative Optical Health Sciences · 2026