Transfer of off-line calibration models to an in-line near-infrared high-speed monitoring system for tablet uniformity.

Cristian Kulcițki, Anna Novikova, Claudia S Leopold

Department of Pharmaceutical Technology, Institute of Pharmacy, University of Hamburg, Bundesstraße 45, D-20146 Hamburg, Germany. · Fette Compacting, Grabauer Straße 24, D-21493 Schwarzenbek, Germany.

Key points

From the paper's conclusion
  • Both, calibration transfer methods as well as the off-line calibration with tablet densities and temperatures similar to those during the in-line spectra acquisition reduced the systematic prediction bias successfully.

Abstract

In-line near-infrared (NIR) spectroscopy is a widely used method to monitor tableting processes. The acquisition of in-line NIR spectra of individual tablets is possible between their compression and ejection stages in the tablet press. It was shown, that in-line spectra used for the API content prediction with off-line calibration models led to a systematic prediction bias. To further investigate factors that may influence this bias, in the present study off-line calibration models were developed with tablets of different densities obtained by varying the compression force which were exposed to either room temperature or a range between 22.3 and 51.5°C during spectral acquisition. Univariate (linear response correction) and multivariate (direct orthogonalization) calibration transfer methods were investigated using off-line and in-line acquired calibration and test spectra with different API contents. The different densities of the calibration tablets and the temperature during calibration had a negligible influence on the calibration models and on the cross-validation results. However, both influencing factors had a major effect on the content prediction bias obtained with in-line spectra. Both, calibration transfer methods as well as the off-line calibration with tablet densities and temperatures similar to those during the in-line spectra acquisition reduced the systematic prediction bias successfully.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Transfer of off-line calibration models to an in-line near-infrared high-speed monitoring system for tablet uniformity — Science Skim