A Novel Single-Needle Distal Return Strategy Achieves Sustained Dialysis Efficacy and Eliminates Reinterventions in High-Risk Arteriovenous Fistulas.

Shan Wu, Linlin Xu, Song Su, Yu Zhang, Huishang Wang, Beibei Wang, Yonglian Guan, Hang Xu,

Blood Purification Center, Affiliated Suzhou Municipal Hospital of Anhui Medical University, Suzhou, China. · Blood Purification Center, The First People's Hospital of Yongkang, Affiliated to Hangzhou Medical College, Yongkang, China.

Observational

Key points

From the paper's conclusion
  • The SNDR technique not only sustained but improved dialysis efficacy while substantially reducing reinterventions, costs, and complications in complex AVF failure. This approach represents a transformative salvage strategy that substantially reduces costs before resorting to catheter-dependent options.

Abstract

RATIONALE & OBJECTIVE: Patients with arteriovenous fistulas (AVFs) facing recurrent interventions endure high procedural burdens and costs. We evaluated a novel single-needle distal return (SNDR) technique in refractory AVF cases to assess its impact on dialysis adequacy, reintervention rates, and economic outcomes. STUDY DESIGN: Single-center retrospective self-controlled study. SETTING & PARTICIPANTS: Twenty-five maintenance hemodialysis patients at a tertiary Chinese center (2021-2025) with AVF failure because of complete outflow occlusion (n = 6), venous hypertension (n = 8), procedural fatigue (n = 5), or inadequate cannulation length (n = 6). FINDINGS: Over a median follow-up of 24 months, SNDR significantly improved dialysis adequacy (median single-pool Kt/V: 1.08 vs 1.46, P < 0.001) and ultrafiltration achievement ratio (72% vs 98%, P < 0.001). The annualized reintervention rate decreased by 90% (3.7 to 0.36 events/year, P < 0.001), access-related costs fell by 88% (¥135,000 to ¥16,000/year, P < 0.001), and temporary catheter use was eliminated in 88% of patients. Safety outcomes improved: dialysis machine alarms decreased from 28 to 3 per 100 sessions (P < 0.001) and hematoma rates from 8.0% to 1.5% of sessions (P < 0.001). Venous pressure remained within safe ranges (124 vs 118 mm Hg, P = 0.15). LIMITATIONS: Single-center retrospective design and modest sample size limit generalizability. CONCLUSIONS: The SNDR technique not only sustained but improved dialysis efficacy while substantially reducing reinterventions, costs, and complications in complex AVF failure. This approach represents a transformative salvage strategy that substantially reduces costs before resorting to catheter-dependent options.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers