Five-year outcomes of chordal replacement therapy for primary mitral regurgitation: The CHAGALL (CHordArt System Study for the Treatment of Mitral ReGurgitAtion due to Leaflet ProLapse or fLail) study.
Alberto Weber, Kestutis Rucinskas, Jodi Akin, Maurizio Taramasso, Michel Zuber, Rolf Vogel, Andrej Podkopajev, Vilius Janusauskas,
Heart Center Hirslanden, Zurich, Switzerland. · Clinic of Cardiovascular Diseases, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.
Key points
From the paper's conclusion- Surgical implantation of the ChordArt chordal replacement system was simple to perform and demonstrated excellent long-term technical durability and sustained clinical performance over 5 years. These findings support further clinical evaluation of this technology and the ongoing development of a fully transcatheter transseptal delivery platform.
Abstract
OBJECTIVES: The CHAGALL (CHordArt System Study for the Treatment of Mitral ReGurgitAtion due to Leaflet ProLapse or fLail) study is a prospective, first-in-human early feasibility study evaluating the technical feasibility, the long-term safety, and device durability of a novel chordal replacement system for the treatment of primary degenerative mitral regurgitation. METHODS: Five patients with symptomatic severe primary degenerative mitral regurgitation attributable to isolated central posterior leaflet prolapse or flail underwent surgical implantation of the ChordArt chordal replacement system through a left atrial approach under cardiopulmonary bypass combined with ring annuloplasty. Clinical and transthoracic echocardiographic follow-up was prospectively performed at discharge and through 60 months. RESULTS: Technical device success was achieved in all patients. Mitral regurgitation was reduced to none or trace immediately after implantation and remained stable throughout the 5-year follow-up. No device-related major adverse events, structural device failure, implant dislodgement, chordal rupture, reoperation, or rehospitalization occurred. Reverse cardiac remodeling was observed, including reduction in left ventricular end-diastolic diameter and left atrial volume, whereas left ventricular function remained preserved during long-term follow-up. CONCLUSIONS: Surgical implantation of the ChordArt chordal replacement system was simple to perform and demonstrated excellent long-term technical durability and sustained clinical performance over 5 years. These findings support further clinical evaluation of this technology and the ongoing development of a fully transcatheter transseptal delivery platform.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Outcomes of 2-Port Totally Endoscopic Mitral Valve Repair with Artificial Chordae for Degenerative Mitral Regurgitation: A Single-Center Experience.Journal of chest surgery · 2026
- Repair of the Anterior mitral leaflet in a growing porcine model using a partially resorbable knitted patch.Interdisciplinary cardiovascular and thoracic surgery · 2026
- Novel Transcatheter Edge-to-Edge Repair System for High-Risk Primary Mitral RegurgitationJACC Asia · 2026
- Severe continuous prosthetic mitral regurgitation from chordal rupture after valve-sparing replacement: a case report.Journal of cardiothoracic surgery · 2026
- Transcatheter edge-to-edge repair for mitral valve regurgitation: insights from a 5-year prospective multicenter registry.The American journal of cardiology · 2026
- Transcatheter Mitral Cerclage Ventriculoplasty: 5-Year Outcomes.Circulation. Cardiovascular interventions · 2026