Long-Term Follow-up Study of Dynesys Dynamic Stabilization: A Single Institution Experience from China.
Tianhong Chen, Zhuowen Hao, Hongliang Zhang, Zhenhua Xu, Jingfeng Li
Department of Orthopedics, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan 430071, China; Tianhong Chen, Zhuowen Hao and Hongliang Zhang should be considered joint first author. · Department of Orthopedics, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan 430071, China. Electronic address: xuzhenhua28@163.com.
Key points
From the paper's conclusion- Dynesys dynamic stabilization combined with decompression was associated with clinical improvement and partial preservation of operative-segment mobility during long-term follow-up.
Abstract
OBJECTIVE: To describe the long-term outcomes of Dynesys dynamic stabilization combined with decompression. METHODS: This study included patients who underwent Dynesys dynamic stabilization plus decompression surgery at Zhongnan Hospital of Wuhan University (Wuhan, China) from January 2008 through December 2014. Clinical efficacy was evaluated using the Visual Analog Scale (VAS), Japanese Orthopaedic Association (JOA) score, Oswestry Disability Index (ODI), and SF-36 quality of life scale. Preoperative and final follow-up imaging was collected to measure the intervertebral disc height and range of motion of the surgical and adjacent segments. The incidence of complications, including adjacent segment disease (ASD) and internal fixation loosening, was recorded. RESULTS: A total of 35 patients were included (mean follow-up: 122 ± 23 months). Follow-up results showed significant improvements in VAS, JOA score, ODI, and SF-36 scores at the final follow-up compared with preoperative values (all P < 0.05). Imaging results showed that at the final follow-up, no significant difference in operative-segment disc height was detected between preoperative and final follow-up measurements (P = 0.518), whereas the disc heights of the cranial and caudal adjacent segments significantly decreased (both P < 0.05). The range of motion of the surgical segment decreased compared with preoperative values , while the range of motion of the cranial and caudal adjacent segments increased compared with preoperative values (P < 0.05). The incidence of symptomatic ASD at the final follow-up was 8.6%. CONCLUSIONS: Dynesys dynamic stabilization combined with decompression was associated with clinical improvement and partial preservation of operative-segment mobility during long-term follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association of diffuse idiopathic skeletal hyperostosis with postoperative outcomes following surgery for degenerative lumbar spine disease.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Evaluation of Clinical and Radiological Outcomes of Rigid, Dynamic, and Hybrid Stabilization Systems in Degenerative Lumbar Spine Surgery.Journal of clinical medicine · 2026
- Predictive radiographic risk factors for adjacent segment degeneration following degenerative lumbar spine fusion: a systematic review and meta-analysis.Neurosurgical review · 2026
- Dynamic instability is associated with worse patient-reported outcome measures after fusion for lumbar degenerative spondylolisthesis: a single-center retrospective cohort study.Journal of spine surgery (Hong Kong) · 2026
- Hypermobile cervical disc arthroplasty: clinical and radiological outcomes at minimum 2-year follow-up.Journal of neurosurgery. Spine · 2026
- Long-term clinical and radiographic outcomes of interlaminar coflex dynamic stabilization versus posterior lumbar interbody fusion for lumbar spinal stenosis: a comparative study with minimum 15-year follow-up.Journal of orthopaedic surgery and research · 2026