World neurosurgery

Short-Term Tolerability and Exploratory Findings of the Cerebrospinal Fluid Refill Test Using Up to 20 mL in Patients With Suspected Cerebrospinal Fluid Hypovolemia.

Eiichi Nakai, Hitoshi Fukuda, Mitsuhiro Takemura, Yu Kawanishi, Tetsuya Ueba

Department of Neurosurgery, Kochi Medical School Hospital, Kochi University, 185-1 Kohasu, Oko-cho, Nankoku, Kochi 783-8505, Japan. Electronic address: enakai@kochi-u.ac.jp. · Department of Neurosurgery, Kochi Medical School Hospital, Kochi University, 185-1 Kohasu, Oko-cho, Nankoku, Kochi 783-8505, Japan.

Observational · n=15

Key points

From the paper's conclusion
  • Pressure-guided CSF replenishment provided preliminary short-term tolerability and feasibility data with variable pressure responses and exploratory symptom improvement. These findings do not establish diagnostic accuracy, an overall safety profile, or superiority of 20 mL over 10 mL.

Abstract

OBJECTIVE: To evaluate short-term tolerability, feasibility, and exploratory physiological responses of a stepwise, pressure-guided cerebrospinal fluid (CSF) refill test using up to 20 mL of artificial CSF in patients with suspected CSF hypovolemia. METHODS: This single-center prospective pilot study enrolled 15 patients. Patients with opening CSF pressure ≤100 mmH2O received 10 mL intrathecally; an additional 10 mL was administered if intermediate pressure was ≤200 mmH2O. Adverse events, CSF pressure, standing headache visual analog scale (VAS), and 10-m walking time were assessed. RESULTS: One patient was ineligible; 14 received artificial CSF. Thirteen completed 20 mL; the second 10-mL aliquot was withheld in one patient because intermediate pressure reached 260 mmH2O. Adverse events occurred in 3 patients: non-serious, related puncture-site pain in 2 and 1 serious adverse event requiring burr-hole surgery for pre-existing rapidly progressive bilateral chronic subdural hematomas, formally assessed as not related to the test. Intermediate and final pressures were higher than opening pressure (both P = 0.001). Standing headache VAS decreased in all 14 patients (median, 47 to 0.5 mm; P < 0.001), but pressure change was not correlated with VAS change (ρ = -0.33, P = 0.32). Median 10-m walking time changed from 11 to 9 seconds (P = 0.19). CONCLUSIONS: Pressure-guided CSF replenishment provided preliminary short-term tolerability and feasibility data with variable pressure responses and exploratory symptom improvement. These findings do not establish diagnostic accuracy, an overall safety profile, or superiority of 20 mL over 10 mL.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers