Water research

Intensity-dependent reversal of magnetic field effects on biofilm-associated fouling in reclaimed water distribution systems.

Zeyuan Liu, Yang Xiao, Liyu Chen, Hongfei Tao, Jiale Wu, Yuhuan Li, Shuli Wei, Rui Tao,

School of Ecology and Environment, Inner Mongolia Key Laboratory of River and Lake Ecology, Inner Mongolia University, Inner Mongolia, Hohhot, 010010, China. · State Key Laboratory of Efficient Utilization of Agricultural Water Resources, College of Water Resources and Civil Engineering, China Agricultural University, Beijing, 100048, China.

Key points

From the paper's conclusion
  • These findings help explain the inconsistent effects previously reported for MF treatment and highlight the importance of field-intensity optimization for reliable fouling control in reclaimed-water distribution systems.

Abstract

Magnetic field (MF) treatment has been proposed as a non-chemical strategy for fouling control in reclaimed-water distribution systems, yet previous studies have reported inconsistent outcomes. Whether these contrasting effects arise from differences in field intensity remains unclear. Here, pilot-scale reclaimed-water distribution systems were operated for 800 h under six MF intensities (0, 10, 30, 100, 300, and 600 mT) to determine how field intensity regulates fouling accumulation and biofilm development. Fouling responses reversed across the intensity gradient. Compared with the untreated control, 10 and 30 mT increased total fouling accumulation by 12.1-13.4% and 24.2-26.7%, respectively, whereas 100, 300, and 600 mT reduced it by 4.5-6.1%, 26.8-27.3%, and 41.9-42.5%, respectively. These changes were accompanied by intensity-dependent microbial physiological responses. Lower-intensity MFs (10-30 mT) induced a moderate increase in ROS-associated fluorescence together with enhanced antioxidant responses, and were associated with sustained cellular activity, greater EPS production, and denser biofilm-associated deposits. Higher-intensity MFs (100-600 mT) produced a much greater ROS-associated fluorescence signal, accompanied by impaired antioxidant defenses, intensified lipid peroxidation, reduced cellular activity, lower EPS production, and more fragmented fouling structures. Metatranscriptomic analysis further revealed clear functional differentiation in fouling communities, with lower-intensity MFs enriching pathways related to colonization, quorum sensing, carbon metabolism, ABC transport, antioxidant defense, and EPS-associated secretion, whereas higher-intensity MFs were associated with stress-related colonization responses, oxidative-stress-associated energy metabolism, and altered EPS/transport-associated functions. Overall, the results support an intensity-dependent reversal in the magnetic-field response within the tested range, with lower-intensity treatments associated with adaptive antioxidant regulation and higher-intensity treatments associated with oxidative damage. These findings help explain the inconsistent effects previously reported for MF treatment and highlight the importance of field-intensity optimization for reliable fouling control in reclaimed-water distribution systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.