Water research

Dynamic coupling and decoupling of odorants and non-CO2 GHGs during sludge treatment: Associations with EPS redistribution and PFS conditioning.

Xinmeng Zhu, Senxiao Lan, Wei Gao, Qiongying Xu, Qiandi Wang, Wenzong Liu

Shenzhen Key Laboratory of Organic Pollution Prevention and Control, State Key Laboratory of Urban-rural Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology, Shenzhen, 518055, PR China. · College of Science, Heihe University, Heihe, 164300, PR China.

Key points

From the paper's conclusion
  • These findings associate the observed coupling-decoupling patterns with EPS redistribution and physicochemical changes, informing stage-specific coordinated management of both pollutant categories.

Abstract

Sludge treatment units in municipal wastewater treatment plants (WWTPs) are major sources of nitrogen- and sulfur-containing odorants and non-CO2 greenhouse gases (GHGs). Although odorant and non-CO2 GHG generation are intrinsically coupled via shared anaerobic metabolic pathways, most studies focus on isolated end-of-pipe emissions, leaving their generation profiles and coupling-decoupling mechanisms under thickening and chemical conditioning largely unexplored. Here, we quantified apparent generation rates and stage-specific pollutant loads across the treatment train, including secondary sludge (SS), thickened sludge (TKS), conditioned sludge (CS), and dewatered sludge (DS). The redistribution of extracellular polymeric substances (EPS) and physicochemical changes were analyzed to develop a mechanistic interpretation of pollutant generation patterns. The results revealed pronounced stage-specific divergence: odorant generation rates increased from 2.5 to 2.8 μg·kg-1·h-1 in SS/TKS to 46.3-111.4 μg·kg-1·h-1 in CS/DS, while the dominant GHG shifted from CH4 to N2O. Secondary sedimentation, thickening, and conditioning accounted for > 97 % of the total estimated load for each pollutant category. Notably, pollutant generation patterns shifted from coupling in TKS to decoupling following conditioning. In thickened sludge, mild EPS redistribution under neutral anaerobic conditions suggested enhanced substrate bioavailability, helping explain the concurrent increases in odorant and CH4 generation. Polyferric sulfate (PFS) conditioning induced asymmetric EPS redistribution and acidic, sulfate-rich conditions; these changes were associated with a sharp increase in odorant generation, near-complete suppression of biological CH4 generation, and transient N2O release through chemical reactions. These findings associate the observed coupling-decoupling patterns with EPS redistribution and physicochemical changes, informing stage-specific coordinated management of both pollutant categories.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Dynamic coupling and decoupling of odorants and non-CO2 GHGs during sludge treatment: Associations with EPS redistribution and PFS conditioning — Science Skim