Water research

Anodic boundary-layer pumping enables membraneless organophosphonate conversion and phosphorus recovery in recirculating cooling water.

Ruoxin Ma, Jie Zhou, Jiqun Li, Yunxian Liu, Wei Yan, Min-Ge Tian, Hao Xu

Department of Environmental Science and Engineering, Xi'an Jiaotong University, Xi'an, 710049, China. · Department of Environmental Science and Engineering, Xi'an Jiaotong University, Xi'an, 710049, China; Xi'an Key Laboratory of Solid Waste Recycling and Resource Recovery, Xi'an Jiaotong University, Xi'an, 710049, China.

Key points

From the paper's conclusion
  • In high-hardness synthetic cooling water, the integrated process achieved 60.0% EDTMP oxidation and 49.5% P recovery alongside sequential hardness removal.

Abstract

Organophosphonate antiscalants in recirculating cooling water resist degradation and limit phosphorus (P) recovery. Here, an anodic-pumping-enhanced membraneless electrochemical system (A-MFES) was developed to couple organophosphonate conversion with P recovery. Directional pumping through a porous Ti/PbO2 anode enhanced contact with electroactive surfaces and transported the acidic interfacial solution containing reactive chlorine into the pumped effluent. Pumping controls, free-chlorine measurements, and quenching responses supported the coupling of interfacial oxidation with continued chlorine-mediated solution-phase oxidation, extending oxidant utilization beyond the electrode surface. Using ethylenebis(nitrilodimethylene) tetraphosphonic acid (EDTMP) as the representative compound, A-MFES achieved 57.1% oxidation during single-pass operation and also converted structurally distinct organophosphonate antiscalants. Coupling with a pumped-cathode precipitation unit enabled 59.6% P recovery as hydroxyapatite-containing calcium phosphate, with 63.5% oxidation in the coupled process. Sustained oxidation during continuous operation and conversion in real recirculating cooling water supported the applicability of the oxidation unit. In high-hardness synthetic cooling water, the integrated process achieved 60.0% EDTMP oxidation and 49.5% P recovery alongside sequential hardness removal. This study establishes directional anodic pumping as a strategy for extending interfacial oxidation into the effluent and integrating organophosphonate conversion with mineral recovery in a membraneless process.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers