A novel passive sampler for simultaneous in situ determination of legacy and emerging per- and polyfluoroalkyl substances in wastewaters and urban rivers.
Zhou Fang, Haiyi Chen, Yuan Li, Danxing Yang, Hao Zhang, Kevin C Jones, Cheng Gu, Jun Luo
State Key Laboratory of Water Pollution Control and Green Resource Recycling, School of Environment, Nanjing University, Nanjing, Jiangsu 210023, PR China. · Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom.
Key points
From the paper's conclusion- These results demonstrate the potential of the MAX-DGT as a robust and versatile tool for in situ monitoring of a broad suite of legacy and alternative PFASs in aquatic environments.
Abstract
The widespread occurrence of per- and polyfluoroalkyl substances (PFASs) in aquatic systems has raised global concern, prompting regulatory actions on several legacy compounds. This study presents a novel diffusive gradients in thin-films (DGT) passive sampler employing a mixed-mode anion exchange (MAX) resin binding layer for simultaneously measuring seven perfluoroalkyl carboxylic acids (PFCAs), five perfluoroalkane sulfonic acids (PFSAs), and two emerging replacement PFASs (6:2 FTSA and GenX). Systematic laboratory evaluation demonstrated that the MAX-DGT device performs reliably across wide environmental gradients: pH from 3.0 to 9.0, ionic strength from 0.001 to 0.5 M NaCl, and humic acid as a dissolved organic matter (DOM) surrogate up to 30 mg L-1, with only marginal effects observed at the highest DOM levels. The MAX binding layer exhibits excellent performance under alkaline conditions where earlier weak anion-exchange phases fail. The mass of PFASs accumulated by the sampler increased linearly with deployment time and varied inversely with diffusive layer thickness, consistent with DGT theory. The binding capacity exceeded 550 μg per device, indicating potential applicability in highly contaminated waters. Field deployments at a wastewater treatment plant and in three urban rivers confirmed that the MAX-DGT sampler provided time-weighted average concentrations in close agreement with repeated grab sampling while also responding to episodic contamination events. These results demonstrate the potential of the MAX-DGT as a robust and versatile tool for in situ monitoring of a broad suite of legacy and alternative PFASs in aquatic environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Covalent organic framework-based DGT sampler for in situ monitoring of per- and polyfluoroalkyl substances in aquatic environments.Talanta · 2026
- PFAS Leaching from Common Sampling Materials Using a Standardized ProtocolGroundwater Monitoring & Remediation · 2026
- Demonstration of a High‐Resolution Passive Profiler for Characterizing the Distribution of PFAS in Groundwater: A Comparison of Methods in the FieldGroundwater Monitoring & Remediation · 2026
- Targeted and Non‐Targeted Analysis of Novel and Legacy Per and Polyfluoroalkyl Substances in River Water by Direct Analysis in Real Time Mass SpectrometryRapid Communications in Mass Spectrometry · 2026
- Comparative Analysis of Influent and Effluent Measurements of Per- and Polyfluoroalkyl Substances (PFAS) at Wastewater Treatment Facilities.Journal of environmental engineering (New York, N.Y.) · 2026
- Combining Nanofiltration and Adsorbents to Achieve Effective PFAS Removal in Wastewater EffluentEnvironmental Science & Technology · 2026