Water research

Larger online performance decline does not necessarily indicate more severe membrane fouling: Evidence from electrodialysis with an anionic surfactant.

Renqiang Cao, Haodong Wei, Jiaxin Wang, Yuping Li, Zhijuan Zhao, Feng Duan, Shaoyuan Shi

Chemistry & Chemical Engineering Data Center, CAS, National Engineering Research Center of Green Recycling for Strategic Metal Resources, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, No.1 North Second Street, Zhongguancun, Haidian District, 100190, China. · Key Laboratory of Special Equipment Safety and Energy-Saving for State Market Regulation, China Special Equipment Inspection & Research Institute, Beijing, 100029, China. Electronic address: zhaozhijuan91@163.com.

Key points

From the paper's conclusion
  • These results indicate that online decline can include substantial contributions from membrane-solution interfacial and adjacent-solution processes, rather than membrane fouling alone.

Abstract

A larger online performance decline is often taken to indicate more severe membrane fouling. However, our results show that this assumption does not always hold. Electrodialysis (ED) was used as a representative electro-driven membrane process to examine this relationship using two commercial anion exchange membranes (AEMs) with sodium dodecylbenzenesulfonate (SDBS) as a model foulant. AEM-A showed a 62.17% relative decline in desalination efficiency at 50 mg/L SDBS, but showed only a 1.62 Ω·cm2 increase in membrane area resistance, limited sulfur retention, and near-complete recovery after feed replacement. AEM-B showed little decline at the same SDBS concentration and a smaller 27.73% relative decline at 300 mg/L, yet showed a 10.80 Ω·cm2 resistance increase, greater sulfur retention, and only partial recovery. Potential-difference measurements and consecutive impedance spectra indicated that rapid, nonstationary resistance buildup at the membrane-solution interface and in adjacent solution regions contributed to the pronounced online decline of AEM-A. These results indicate that online decline can include substantial contributions from membrane-solution interfacial and adjacent-solution processes, rather than membrane fouling alone. A simple feed-replacement recovery test can complement online monitoring by helping distinguish largely recoverable transport disturbances from persistent membrane-associated effects. Integrating online performance, feed-replacement recovery, and post-operation membrane characterization may provide a more complete basis for membrane fouling assessment in ED.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers