Dynamic carbon aware multi-pump scheduling in water distribution systems: Carbon-pressure margin trade-offs under seasonal storage conditions.
Yisong Zhu, Wencheng Ma, Dan Zhong
State Key Laboratory of Urban-rural Water Resources and Environment, Harbin Institute of Technology, Harbin, 150090, China. · State Key Laboratory of Urban-rural Water Resources and Environment, Harbin Institute of Technology, Harbin, 150090, China. Electronic address: zhongdan@hit.edu.cn.
Key points
From the paper's conclusion- Accordingly, this paper establishes a multi-pump independent variable-speed scheduling framework that couples dynamic grid carbon intensity, controlled seasonal water demand, and storage conditions to balance operational carbon emissions and the modified resilience index (MRI), a normal-operation pressure-margin proxy.
Abstract
The low-carbon transition of urban water distribution systems (WDSs) requires embedding emission reduction targets into daily operations. Optimizing multi-pump scheduling while ensuring water supply security is a key approach to reducing operational carbon emissions. However, seasonal water demand, storage capacity, and hydraulic limitations constrain scheduling flexibility. Their effects on emission reductions remain insufficiently characterized. Accordingly, this paper establishes a multi-pump independent variable-speed scheduling framework that couples dynamic grid carbon intensity, controlled seasonal water demand, and storage conditions to balance operational carbon emissions and the modified resilience index (MRI), a normal-operation pressure-margin proxy. To address constrained search, this paper proposes a learning-assisted scenario-enhanced evolutionary optimization method (LASEO-SE), which utilizes target-excluded historical candidates organized by scenario and objective stratum to improve the search prior. The method evaluates candidate solutions through independent hydraulic simulations. LASEO-SE attained the lowest mean carbon emissions and the highest mean MRI endpoints in five and three of seven D-town scenarios, and achieved the highest mean normalized hypervolume among all feasible scenarios. Against matched energy-minimization controls, mean carbon advantages were positive in four scenarios and negative in three, with no significant paired differences after Holm correction. On the actual T-city network, LASEO-SE identified strictly feasible low-carbon schedules, while the best-performing method varied across metrics. Urban WDSs can be considered flexible energy infrastructure subject to hydraulic constraints; by coordinating dynamic grid carbon signals with water-side storage flexibility, operational emissions reductions can expand from energy-consumption cuts to system-level decisions that balance temporal carbon benefits with pressure margin and water-supply security.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Carbon-Aware Scheduling of Flexible Electricity Loads via Fuel-Mix-Derived Grid Carbon Intensity: An ISO New England Case StudyAdvances in Carbon Neutrality · 2026
- Multi-Timescale Coordinated Scheduling of Pumped Water Supply and Transfer Systems: Bridging Water Allocation, Economic Operation, and Hydraulic SafetyApplied Sciences · 2026
- A Waterlogging Defense Strategy With Cross-Domain Data-Driven Risk Prediction for Coupled Power and Drainage SystemsIEEE Transactions on Smart Grid · 2026
- Decision-Focused Learning for Water Treatment Plant Operations: Deterministic versus Stochastic FormulationsACM Transactions on Sensor Networks · 2026
- Physics-informed ensemble machine learning for dynamic water quality prediction in water distribution systemsJournal of Water Process Engineering · 2025
- Energy flexibility strategies in urban areas: A sustainable energy consumption and production balance under a stochastic frameworkRenewable and Sustainable Energy Reviews · 2026